Monitoring the Unit
4-13
7976-A2-GB20-10
August 1998
Model 7976 Standalone Termination Unit LEDs
The following table contains a description of the LEDs on the Model 7976
Standalone Termination Unit front panel.
PO
WER
ALARM TEST
DSL
G.703
98-16003
7976 M/SDSL
TM
TM
Type
LED
LED is . . .
Indicating . . .
General
POWER
Green
Off
Green,
Flashing
Unit has power.
No power to the Unit.
Unit is in minimum mode and a download is
required.
ALARM
Red
Off
Device failure, or Power-On Self-Test (POST)
has failed.
Self-test passed.
TEST
Amber
Amber,
flashing
Off
Loopback test or 511 test pattern in progress.
Self-test in progress.
No tests.
DSL
DSL
Green
Amber
Amber,
flashing
Off
DSL link is up.
DSL training in progress.
An OOF condition exists.
The DSL Link is down.
G.703
DTE
Green
Amber
Amber,
flashing
Off
Recoverable signal present on the G.703
network.
Remote Alarm Indication (RAI) present.
An OOF or AIS condition exists.
The DSL LINK is down.