Configuration Option Tables
A-18
7976-A2-GB20-10
August 1998
Table A-7.
SNMP Traps Options (3 of 3)
Link Traps
Possible Settings: Disable, Up, Down, Both
Default Setting: Both
Determines if SNMP traps are generated for link up and link down for one of the
communication interfaces.
Disable – No
linkUp or linkDown SNMP traps are generated.
Up – A
linkUp trap is generated when the Model 7976 Termination Unit recognizes that
one of the communication interfaces is operational.
Down – A
linkDown trap is generated when the Model 7976 Termination Unit
recognizes a failure in one of the communication interfaces.
Both – Sends trap messages for detection of both
linkUp and linkDown.
NOTE:
Refer to
linkUp and linkDown
in Appendix B, Standards Compliance for
SNMP Traps.
Link Trap Interfaces
Possible Settings: Network, SYNC, All
Default Setting: All
Determines if the SNMP
linkUp, SNMP linkDown, and interface-related
enterpriseSpecific traps are generated for the network interface, synchronous data
(DTE) port, or both.
Network – SNMP trap messages are generated for the network interface.
G.703 – SNMP trap messages are generated for the G.703 port.
All – SNMP trap messages are generated for the network E1 interface and the G.703
ports.
Summary of Contents for Hotwire 7976
Page 56: ...Monitoring the Unit 4 14 7976 A2 GB20 10 August 1998 This page intentionally left blank...
Page 66: ...Testing 5 10 7976 A2 GB20 10 August 1998 This page intentionally left blank...
Page 78: ...Security 7 6 7976 A2 GB20 10 August 1998 This page intentionally left blank...
Page 104: ...Standards Compliance for SNMP Traps B 6 7976 A2 GB20 10 August 1998...
Page 112: ...Technical Specifications D 2 7976 A2 GB20 10 August 1998...