A. Configuration Options
A-14
September 2004
7990-A2-GB20-20
System Options
For System Options, refer to
Table A-6, System Options
. To access the System
Options screen, follow this menu selection sequence:
Main Menu
→
Configuration
→
Current Configuration
→
System
Table A-6.
System Options (1 of 3)
DSL Mode
Possible Settings:
STU-C
,
STU-R
Default Setting:
STU-R
Controls whether the unit is configured as a SHDSL Transceiver Unit – Central Site
(STU-C) or a SHDSL Transceiver Unit – Remote Terminal Site (STU-R).
STU-C
– The unit is configured as a SHDSL Transceiver Unit – Central Site. An STU-C is
typically found at the central office. The STU-C polls the STU-R and controls the system
startup procedure, the timing of the loop, and the communication of the maintenance
channel.
STU-R
– The unit is configured as a SHDSL Transceiver Unit – Remote Terminal Site. An
STU-R is typically found at the customer premises.
NOTE: Changing this option resets the unit.
main/config/system
Model: 799x
SYSTEM OPTIONS
DSL Mode: STU-C
Test Timeout: Enable
Test Duration (min): 10
G.703 Line Termination: 120 Ohm
(Model 7996)
Region Setting: Annex B
Spectrum Management: Disable
Country Code: UK
--------------------------------------------------------------------------------
Ctrl-a to access these functions, ESC for previous menu MainMenu Exit
Save
Summary of Contents for Hotwire 7995
Page 16: ...1 About the TDM SHDSL Endpoint 1 8 September 2004 7990 A2 GB20 20...
Page 42: ...3 Initial Startup and Configuration 3 18 September 2004 7990 A2 GB20 20...
Page 48: ...4 Configuring the Unit Using the Internal Switches 4 6 September 2004 7990 A2 GB20 20...
Page 91: ...7 Testing 7990 A2 GB20 20 September 2004 7 15...
Page 92: ...7 Testing 7 16 September 2004 7990 A2 GB20 20...
Page 132: ...B Standards Compliance for SNMP Traps B 8 September 2004 7990 A2 GB20 20...
Page 146: ...C Connectors Cables and Pin Assignments C 14 September 2004 7990 A2 GB20 20...
Page 148: ...D Technical Specifications D 2 September 2004 7990 A2 GB20 20...