5. Diagnostics
8335-A2-GB20-A0
March 2005
5-7
Card Alarms Screen – Model 8355 and Model 8375
(Continued)
D-B
Minor Alarms
:
Config Error
– If ALARM appears on this line, the card has detected a checksum error in
the memory where the configuration is stored.
Loss of Cell Delineation
– If a loss of cell delineation has been detected on the port, an
A (for Alarm) appears in the column for that port.
Loss of Signal
– If a loss of signal has been detected on the port, an A (for Alarm)
appears in the column for that port.
Loss of Power
– The endpoint (ATU-R) has lost power.
Loss of Frame
– A Loss Of Frame (LOF) condition exists. A LOF is declared after
approximately 2 seconds of contiguous Severely Errored Frames (SEF).
Loss of Signal Quality
– A Loss of Signal Quality (LOSQ) condition exists. A LOSQ
condition exists when the noise margin falls below the minimum noise margin (0 dB) or the
BER exceeds 10
-7
for 3 seconds, or when the rate falls below the minimum configured
rate for 3 seconds.
Error Seconds Threshold
–The number of Errored Seconds has exceeded the
user-defined threshold.
Severely Errored Seconds Threshold
– The number of Severely Errored Seconds has
exceeded the user-defined threshold.
Unavailable Seconds Threshold
– The number of Unavailable Seconds has exceeded
the user-defined threshold.
Increasing Rate Threshold
– The current rate is
≥
the previous rate plus the
user-defined threshold.
Decreasing Rate Threshold
– The current rate is
≤
the previous rate plus the
user-defined threshold.
Table 5-2.
Monitoring – Card Alarms (3 of 6)