7. Monitoring and Troubleshooting
7-16
May 2002
8700-A2-GB20-40
Status: Contains the contents of the status events register. The status events
register maintains a history of specific events that have occurred during an
interval. Values include:
— Y: Remote alarm indication signal (yellow alarm) received at the DSX-1
interface
— L: Loss of signal detected at the DSX-1 interface
— E: Excessive error rate threshold exceeded
— F: Frame synchronization bit error detected
— V: Line code violation detected
— None: No significant events have occurred
Fields on this screen include:
Field . . .
Contains . . .
Current Interval Timer
The number of seconds which have elapsed in the current
15-minute interval. Maximum value is 900 seconds
(15 minutes). This counter is reset every 15 minutes.
When zero, the port is disabled.
Error Events Counter
A running total of CRC and OOF events. Range = 0– 65535.
This counter is reset when the statistics are cleared.
When zero, the port is disabled.
Current Int
Performance data for the current 15-minute interval. When
blank, the port is disabled.
Interval
xx
Historical performance data for up to 96 15-minute intervals
(24 hours) where the value of
xx is from 01 to 96. When blank,
the port is disabled.
Worst Interval
Identifies the interval during which the most error events were
detected. When blank, the port is disabled.
Tot
A running total of the performance statistics.
Summary of Contents for Hotwire 8777
Page 22: ...2 Using the Asynchronous Terminal Interface 2 10 May 2002 8700 A2 GB20 40 ...
Page 36: ...3 Initial Startup and Configuration 3 14 May 2002 8700 A2 GB20 40 ...
Page 44: ...4 Cross Connecting Ports 4 8 May 2002 8700 A2 GB20 40 ...
Page 52: ...6 Security 6 6 May 2002 8700 A2 GB20 40 ...
Page 96: ...9 Transferring Firmware and Configurations Using TFTP 9 6 May 2002 8700 A2 GB20 40 ...
Page 148: ...C Connector Pin Assignments C 4 May 2002 8700 A2 GB20 40 ...
Page 150: ...D Technical Specifications D 2 May 2002 8700 A2 GB20 40 ...