4. Monitoring the Card
8799-A2-GB20-10
April 2003
4-5
LMI Discovery in
Prog, IBMC
The Local Management
Interface protocol discovery is
being performed to determine
the protocol to be used by the
Inband Management Channel.
1. Check the LMI type on the
router.
2. Check the G.703 interface.
LMI Down, IBMC
The Local Management
Interface is down for the
Inband Management Channel.
1. Check the LMI type on the
router.
2. Check the G.703 interface.
LOF at G.703, Pt
n
An LOF (Loss Of Frame)
condition has been detected
on the G.703 interface.
1. Verify that the Line Framing,
Line Coding, and TimeSlot 16
configurations are compatible
with the attached equipment.
2. Check the G.703 interface
cable.
LOS at DSL, Pt
n
An LOS (Loss Of Signal)
condition has been detected
on the DSL interface. No signal
is being received on Port
n,
possibly due to a local network
problem.
1. Verify that the network cable is
securely attached at both
ends.
2. Verify proper STU-R and
STU-C configuration.
3. Contact network provider to
troubleshoot the line.
LOS at G.703, Pt
n
An LOS (Loss Of Signal)
condition has been detected
on the network interface. No
signal is being received on
Port
n, possibly due to a local
network problem.
1. Verify that the G.703 cable is
securely attached at both
ends.
2. Verify the G.703 cable for
correct pin assignments with
attached equipment.
3. Contact network provider to
troubleshoot the line.
Primary Clock
Failed, Pt
n
A failure has occurred in the
primary clock source for the
G.703 port. Timing is being
supplied by the fallback clock.
1. Verify that the G.703 cable is
securely attached at both
ends.
2. Verify the clock configuration.
3. Contact network provider.
Primary IBMC
Down
The port configured for the
primary inband managemnet
channel has failed, and the
backup IBMC, if available, is
active.
Troubleshoot the port.
Table 4-1.
Health and Status Messages (3 of 4)
Message
What Message Indicates
What To Do