2. Installation
8820-A2-GN20-30
March 2001
2-19
Procedure
To remove the multislot filler plate:
1. Remove the screws fastening the filler
plate to the chassis.
2. Lift the filler plate away from the chassis.
Procedure
To adjust the multislot filler plate to cover empty slots:
CAUTION:
Breakaway may cause sharp edges and burrs. Use due care.
1. Count the number of DSL cards that you will be installing.
— If you are installing fewer
than 8 cards, go to
— If you are installing cards
in Slots 1 through 8 or
10 through 17, remove the
appropriate multislot filler
plate (use tabs provided).
2. From the side of the multislot
filler plate without the EMI
gaskets, break away as many
panels as needed.
NOTE:
Be sure to break off panels
from the side of the filler plate
opposite the EMI gaskets. The
edge with the the EMI gaskets
is needed to create a good EMI
seal with the card in the slot to
the left of the filler plate.
ALARMS
Major Minor
Fan
B
A
POWER
SERIAL
SMCM
CLOCK
A
ALARM
2
4
6
8
10
12
14
16
18
1
3
5
7
9
11
13
15
17
LAN/WAN SLOT
B
CLOCK
B
A
SERIAL
MCC
AC
ALARM
48V R
T
N
48V NEG
POWER ENTRY MODULE
LEFT UNIT: LINE A
RIGHT UNIT: LINE B
WARNING! POWER MUST BE DISCONNE
CTED AT THE SOURCE
BEFORE REMOVING OR INSTALLING THIS PWR ENTR
Y MODULE
48V R
T
N
48V NEG
POWER ENTRY MODULE
LEFT UNIT: LINE A
RIGHT UNIT: LINE B
WARNING! POWER MUST BE DISCONNECTED A
T THE SOURCE
BEFORE REMOVING OR INSTALLING THIS PWR ENTR
Y MODULE
DSL
SYSTE
M
OK
Alm
Test
ETHERN
ET
TX
RX
Coll
DSL PO
RT
1
2
3
4
MCP
SYSTEM
OK
Alm
Test
ETHERNE
T
TX
RX
Coll
00-16260a-02
Slot 1
Screws
Screws
Slot 18
Multislot Filler Plate
Rear View
Break at Score
99-16261-01
Caution
Label
EMI
Gaskets