3. Cabling
3-6
March 2001
8820-A2-GN20-30
Connecting CO Alarm to the Alarm System
The following procedure is optional. Follow this procedure only if you want to
connect to a CO alarm system. See
Procedure
To connect the Hotwire 8820 GranDSLAM to a CO alarm system:
1. Plug an 8-pin modular cable into the ALARM port of the chassis.
2. Dress the cable to the right in the cable tray.
3. Remove the modular plug connector at the end of the cable, strip the wires
and connect to the desired CO alarm system outputs.
Connecting Ethernet Connections to the IPC, Ethernet Hubs or
Switches
Use this procedure for connecting RADSL, MVL, ReachDSL/MVL, IDSL, and
SDSL cards to the IPC, Ethernet hubs or switches. For other types of cards, refer
to the appropriate Installation Instructions.
Procedure
To connect the Hotwire 8820 GranDSLAM to the IPC, Ethernet hubs or switches:
1. Plug an 8-pin modular UTP CAT5 cable into LAN jack Port 1 for connecting the
LAN wiring from the DSL card in Slot 1. Repeat this step for jack Port 2 for the
DSL card in Slot 2, etc.
2. Dress the cable(s) to the right and through the cable retainer.
3. Plug the other end of the cable into your IPC, Ethernet hub connector, or
switch.
Alarm
00-16558-01
SERIAL
SCM
CLOCK
A
ALARM
2
4
6
8
10
12
14
16
18
1
3
5
7
9
11
13
15
17
LAN SLOT
B
CLOCK
B
A
SERIAL
MCP
AC
ALARM
SERIAL
SCM
CLOCK
A
ALARM
2
4
6
8
10
12
14
16
18
1
3
5
7
9
11
13
15
17
LAN SLOT
B
CLOCK
B
A
SERIAL
MCP
AC
ALARM
LAN Slot
Port 1
99-16559