18
3.
Save the configuration.
4.
Return to the Main Menu.
If trap dial-out is desired, the PC or asynchronous terminal must be disconnected from
the unit’s COM port when setup is complete, and an external modem connected instead.
See
Setting Up Call Directories for Trap Dial-Out
and in the
iMarc Configuration
Reference
for additional information.
Verifying the End-to-End Path
After installation of a remote site unit, run an IP Ping test to ping the NMS at the central
site and verify that the entire path from the remote unit to the NMS is functioning. To run
the IP Ping test, NMS trap managers must have been configured for the remote unit.
One of those trap managers must be the central site NMS.
Procedure
1.
Select the IP Ping test.
Main Menu
→
Test
→
IP Ping
2.
Enter the IP Address of the device being pinged, then select Start.
NOTE:
When running tests, the cursor is positioned over the Start command. Press
Enter to start the test. Stop is displayed while the test is running. Press Enter
again to issue the Stop command.
—
While the test is running,
In Progress...
appears in the Status field.
—
When the test is finished,
Alive. Latency =
nn
ms
should appear as the
Status (
nn
being the amount of time the test took in milliseconds).
If any other message is displayed, additional testing will be required.
See
Device Messages
in the
iMarc Operations Guide
for information about IP
Ping-related messages.