Monitoring the Unit
4-3
7986-A2-GB20-00
September 1998
Health and Status
The following messages can appear in the first column of the System and Test
Status screen. The highest priority Health and Status message also appears on
all ATI screens on the bottom right.
Table 4-1.
Health and Status Messages (1 of 2)
Message
What Message Indicates
What To Do
System Operational
There are no problems
detected.
LOS at Net, Pt 1
An LOS (Loss Of Signal)
condition has been
detected on the network
interface. No signal is
being received on Port 1,
possibly due to a local
network problem.
1. Verify that the network cable is
securely attached at both ends.
2. Contact network provider.
OOF at Net, Pt 1
An OOF (Out Of Frame)
condition has been
detected.
1. Check the Transmit Clock Source
configuration options. Do not set
both the local and remote unit to
Internal, External, or Loop timing.
2. Contact network provider.
LOF at G.703, Pt 1
An LOF (Loss Of Frame)
condition has been
detected on the G.703
interface.
1. Verify that the network cable is
securely attached at both ends.
2. Contact network provider.
AIS at G.703, Pt 1
An Alarm Indication Signal
(AIS) is being received by
the G.703 interface.
1. Check the Transmit Clock Source
configuration options. Do not set
both the local and remote unit to
Internal, External, or Loop timing.
2. Contact network provider.
EER at Net, Pt 1
An EER (Excessive Error
Rate) condition has been
detected on the network
interface at Port 1. The
condition is cleared when
the error rate falls below
the threshold value
currently configured.
Contact network provider.
EER at G.703, Pt 1
An EER (Excessive Error
Rate) condition has been
detected on the G.703
interface.
Contact network provider.
RAI (Remote Alarm
Indication) at G.703
interface, Pt 1
An Remote Alarm
Indication signal is being
received by the G.703
interface.
Contact network provider.
Net Margin
Threshold, Pt 1
The signal-to-noise margin
has exceeded the
configured threshold.
Contact network provider.
Summary of Contents for M/HDSL Standalone Termination Unit HOTWIRE...
Page 68: ...Testing 5 10 7986 A2 GB20 00 September 1998 This page intentionally left blank...
Page 80: ...Security 7 6 7986 A2 GB20 00 September 1998 This page intentionally left blank...
Page 106: ...Standards Compliance for SNMP Traps B 6 7986 A2 GB20 00 September 1998...
Page 114: ...Technical Specifications D 2 7986 A2 GB20 00 September 1998 This page intentionally left blank...