Monitoring the Unit
4-5
7986-A2-GB20-00
September 1998
Self-Test Results
The results of the last power-up or reset self-test appear in the middle column of
the System and Test Status screen.
Table 4-2.
Self-Test Results Messages
Message
What Message Indicates
What To Do
CPU Failed
The CPU failed internal testing.
1. Reset the unit and try again.
DeviceFailed
One or more of the Unit’s integrated
circuit chips failed device-level
testing.
2. Call your service
representative for assistance.
G.703
Failed, Pt 1
The Unit failed to loop data on the
G.703 on Port 1.
1. Reset the unit and try again.
2. Call your service
Memory
Failed
The Model 7986 Standalone
Termination Unit failed memory
verification.
2. Call your service
representative for assistance.
Failure
xxxxxxxx
An internal failure occurred.
(xxxxxxxx represents an eight-digit
hexadecimal failure code for use by
service personnel.)
Record the failure code and
contact your service
representative.
Passed
No errors were detected.