Configuration Option Tables
A-14
7986-A2-GB20-00
September 1998
Table A-6.
Communication Protocol Options (1 of 2)
Node IP Address
Possible Settings: 000.000.000.000 – 223.255.255.255
Default Setting: 000.000.000.000
Specifies the Node IP address. This option is only available when the standalone unit is
configured as an LTU.
Address Field – (000.000.000.000 – 223.255.255.255) – Enter an IP address for the
node. The range for the first byte is 000 to 223, with the exception of 127. The range for
the remaining three bytes is 000 to 255.
Clear – Clears the IP address field and sets to all zeros.
Node Subnet Mask
Possible Settings: 000.000.000.000 – 255.255.255.255
Default Setting: 000.000.000.000
Specifies the Node Subnet Mask. This option is only available when the standalone unit
is configured as an LTU.
Address Field – (000.000.000.000 – 255.255.255.255) – Enter an address for the
Node Subnet Mask.
Clear – Clears the address field and sets to all zeros.
Default Network Destination
Possible Settings: None, COM, DSL
Default Setting: None
Specifies where the default management network is connected, for example, if your
default network is connected to the COM port, select COM as the default management
network destination.
None – No default destination is defined. Data that cannot be routed is discarded.
COM – The unit’s COM port is the default network destination. This option is only
available when the Port Use option on the Communication Port Options menu is set to
Net Link.
DSL – The unit’s DSL port is the default network destination.
Communication Port IP Address
Possible Settings: 000.000.000.000 – 223.255.255.255
Default Setting: 000.000.000.000
Specifies the unit’s Communication Port IP Address when the unit is configured as a
network communication link. This option is only used when the Port Use option on the
Communication Port Options menu is set to Net Link. If the COM Port IP address is not
set (000.000.000.000) the node IP address specified by the Node IP Port will be used.
Address Field – (000.000.000.000 – 223.255.255.255) – Enter an IP address for the
Communication Port. The range for the first byte is 000 to 223, with the exception of
127. The range for the remaining three bytes is 000 to 255.
Clear – Clears the IP address and sets to all zeros.
Summary of Contents for M/HDSL Standalone Termination Unit HOTWIRE...
Page 68: ...Testing 5 10 7986 A2 GB20 00 September 1998 This page intentionally left blank...
Page 80: ...Security 7 6 7986 A2 GB20 00 September 1998 This page intentionally left blank...
Page 106: ...Standards Compliance for SNMP Traps B 6 7986 A2 GB20 00 September 1998...
Page 114: ...Technical Specifications D 2 7986 A2 GB20 00 September 1998 This page intentionally left blank...