EMI Notices

United States – EMI Notice

This equipment has been tested and found to comply with the limits for a Class A digital 
device, pursuant to Part 15 of the FCC rules. These limits are designed to provide 
reasonable protection against harmful interference when the equipment is operated in a 
commercial environment. This equipment generates, uses, and can radiate radio 
frequency energy and, if not installed and used in accordance with the instruction 
manual, may cause harmful interference to radio communications. Operation of this 
equipment in a residential area is likely to cause harmful interference in which case the 
user will be required to correct the interference at his own expense.

The authority to operate this equipment is conditioned by the requirements that no 
modifications will be made to the equipment unless the changes or modifications are 
expressly approved by Paradyne Corporation.

If the equipment includes a ferrite choke or chokes, they must be installed as described 
in the installation instructions.

Canada – EMI Notice

This Class A digital apparatus complies with Canadian ICES-003.

Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada.

CE Marking

When the product is marked with the CE mark on the equipment label, a supporting 
Declaration of Conformity may be downloaded from the Paradyne World Wide Web site 
at 

www.paradyne.com

. Select 

Library 

 Technical Manuals 

 

CE Declarations of 

Conformity

.

Important Safety Instructions

1.

Read and follow all warning notices and instructions marked on the product or 
included in the manual.

2.

Slots and openings in the cabinet are provided for ventilation. To ensure reliable 
operation of the product and to protect it from overheating, these slots and 
openings must not be blocked or covered.

3.

Do not attempt to service this product yourself, as opening or removing covers may 
expose you to hazardous voltage or to other risks. Refer all servicing to qualified 
service personnel.

4.

General purpose cables are used with this product for connection to the network. 
Special cables, which may be required by the regulatory inspection authority for the 
installation site, are the responsibility of the customer. Use a UL Listed, CSA 
certified, minimum No. 26 AWG line cord for connection to the Digital Subscriber 
Line (DSL) network.

!

Summary of Contents for SMD2000-24E

Page 1: ...k Interface Modules Optional 5 Tabletop Installation 7 Rack Installation 8 Powering Up the SMD2000 24E 9 Connecting the SHDSL RJ21 Cable 11 Connecting to the Remote SHDSL Modems 12 Verifying the Conne...

Page 2: ...notice to Paradyne and an agreement in writing to additional terms 3 The Licensee shall not reverse engineer decompile or disassemble the Software in whole or in part 4 The Licensee shall not copy the...

Page 3: ...not be assigned sublicensed or otherwise transferred by the Licensee to any third party without the prior written consent of Paradyne 8 This Agreement and the license granted under this Agreement shal...

Page 4: ...ur sales representative Site Selection Criteria In choosing a location for the installation of this product Select a restricted access area where admittance is limited to trained and authorized servic...

Page 5: ...uires an Ethernet uplink connection or if you require an additional E1 or T1 backhaul The SMD2000 24E supports the following 1 port UIMs only UIM E1 UIM T1 UIM 10 100 CAUTION Disconnect all power sour...

Page 6: ...e lip of the SMD2000 24E faceplate at the selected port opening such that the UIM PCB is face down and the UIM label shows through the port opening with the UIM model name along the right edge 4 Align...

Page 7: ...inal eight flathead screws as depicted in Step 1 on page 5 Tabletop Installation Procedure To install the SMD2000 24E on a table desk shelf or remote cabinet 1 Affix the four provided rubber pads to t...

Page 8: ...e chassis onto the rack and secure the rack mount brackets to the sides of the rack using one of the two provided sets of four rack mount screws whichever size fits the rack being used 3 Check the rac...

Page 9: ...r ground wire with the two holes on the small unpainted section on the left side of the back of the chassis Secure the terminal lug to the chassis with two 10 32 screws 2 Connect the other end of the...

Page 10: ...he screw into the terminal block same terminal from which it was removed 5 Remove the right hand screw labeled from the same terminal block slide the ring terminal of your negative lead onto the shaft...

Page 11: ...However if you wish to run subscriber lines at settings other than the SMD2000 24E defaults configure the subscriber lines prior to connection Parameter settings may be changed using the Command Line...

Page 12: ...or 180 degree cable both the left and right sides of the RJ21 plug connector should be secured to the socket Connecting to the Remote SHDSL Modems A primary feature of the SMD2000 24E is its capabili...

Page 13: ...nfigured prior to connection if you intend to run the group with parameter settings other than the defaults Single Line SHDSL Connection A single line SHDSL subscriber connection may be established wi...

Page 14: ...equires only one uplink connection for operational purposes although a second E1 uplink connection may be desired for redundancy Additionally the two E1 uplink ports may be bonded together for a singl...

Page 15: ...0 0 0 0 Protocol All Speed 272 kbps VLAN Priority 0 none VLAN Range 0 0 off Table 2 E1 Defaults Parameter Default Frame Type Cyclic Redundancy Check CRC Line Code High Density Bipolar 3 Zeros Substitu...

Page 16: ...nagement VLAN ID 0 off TFTP Trivial File Transfer Protocol on Management IP Address Filter Range 0 0 0 0 255 255 255 255 all Uplink DSLAM Interconnection 1 neither off Table 4 Username and Password De...

Page 17: ...loses power unless deliberately cleared or reconfigured Saving to Local Files SMD2000 24E management and port configurations can be uploaded to a local file on your PC or local network via the Trivial...

Page 18: ...4 6 8 A dash indicated range nvr_portcfg bin Password 1 6 12 Or using the keyword all nvr_portcfg bin Password 1 all Table 7 Template Criteria Item Data Needed for Backup Example Host Name DSLAM_IP Ad...

Page 19: ...l default settings To clear the system press the Reset Button for one second release and within five 5 seconds press the Reset Button again for one second After the first pressing of the Reset Button...

Page 20: ...s constant rate Table 9 LEDs 1 of 3 State Indication Additional Information PWR power Solid green SMD2000 24E is receiving power Both power terminals are connected Solid amber SMD2000 24E is receiving...

Page 21: ...pertain to remote network access of the SMD2000 24E LK E1 Uplink Port 1 and 2 Flashing green E1 uplink connection is established and active The uplink port has received valid data from the remote E1...

Page 22: ...te E1 provider equipment has lost a connection with an intermediate device and is receiving an AIS or RAI SHDSL LK Ports 1 24 Flashing green SHDSL connection is established and active The port has rec...

Page 23: ...or Pins Ring Tip Port 1 1 26 Port 13 13 38 Port 2 2 27 Port 14 14 39 Port 3 3 28 Port 15 15 40 Port 4 4 29 Port 16 16 41 Port 5 5 30 Port 17 17 42 Port 6 6 31 Port 18 18 43 Port 7 7 32 Port 19 19 44 P...

Page 24: ...thernet RJ45 Connection Pin Connection 1 Rx 2 Rx 3 Tx 4 not used 5 not used 6 Tx 7 not used 8 not used Table 12 E1 RJ45 Pin Assignments Pin Function Pin 1 Rx Ring Pin 2 Rx Tip Pin 3 not used Pin 4 Tx...

Page 25: ...Pins not shown are unused Table 13 DB9 to 8 Pin Modular Adapter Pinouts Pin 8 Pin Modular Port Direction PC RS232 Serial Port Pin 1 Transmit Data TxD RxD Receive Data 2 2 Data Set Ready DSR RTS Reque...

Page 26: ...15 CSA C108 8 EN55022 EN55024 Safety UL 1950 CSA C22 2 No 950 EN60950 CE Marking Environment Operating Temperature 40 F to 149 F 40 C to 65 C Storage Temperature 40 F to 158 F 40 C to 70 C Humidity 5...

Page 27: ...lass A digital apparatus complies with Canadian ICES 003 Cet appareil num rique de la classe A est conforme la norme NMB 003 du Canada CE Marking When the product is marked with the CE mark on the equ...

Page 28: ...nstall telephone wiring during a lightning storm Never install telephone jacks in wet locations unless the jack is specifically designed for wet locations Never touch uninsulated telephone wires or te...

Reviews: