A-1
3981-A2-GN31-20
November 1996
Technical Specifications
Overview
A-1
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Overview
Table A-1 shows the technical specifications for certain
elements of the WDG. For specific component
information, see the ACCULINK Access Controller
Reference Guide, COMSPHERE 3000 Series Carrier
Installation Manual, – 48 Vdc Central Office Power Unit
Installation Guide, and the COMSPHERE 3800Plus
Modems User’s Guide.
Table A-1
(1 of 2)
Technical Specifications for the Wireless Data Gateway
Technical Specifications
Criteria
ENVIRONMENT
Operating Temperature
Relative Humidity
Storage Temperature
Shock and Vibration
32
_
F (0
_
C) to 122
_
F (50
_
C)
5% to 90% (noncondensing)
– 4
_
F (–20
_
C) to 158
_
F (70
_
C)
Withstands normal shipping and handling
APPROVALS
FCC
Underwriters Laboratories, Inc. (UL)
Recognized Component
Canadian Standards Association
Certified Component
Part 15, Class A
UL Standard for Safety, UL 1950, Second Edition
CSA Standard C22.2 No. 950-M89
COMPATIBILITY
MODULATIONS AND VF RATES
Proprietary V.34 (33,600, 31,200 bps)
ITU-T V.34 (28,800, 26,400, 24,000, 21,600, 19,200, 16,800,
14,400, 12,000, 9600, 7200, 4800, 2400 bps)
V.32
terbo (19,200, 16,800 bps)
CCITT V.32bis (14,400, 12,000, 9600, 7200, 4800 bps)
CCITT V.32 9600, 4800 bps)
CCITT V.22bis (2400 bps)
CCITT V.22 (1200 bps)
Bell 212A (1200 bps)
ERROR CORRECTION PROTOCOLS
ETC, MNP 10
A