Assembly Instructions
ASSEMBLY INSTRUCTIONS
Standard 20 lb. tank
11
handling code, B149.2.
lation Code, CSA B149.1, or propane storage and
ANSI Z223.1/NFPA54, natural gas and propane Instal-
the absence of local codes,with national fuel gas code,
The installation must conform with local codes, or in
assembly supplied with the appliance must be used.
full input rating. The pressure regulator and hose
required input rating for a heater at ratings less than
adjustment. The minimum hourly of 16
,
000 Btu/hr is
supply pressure: 5 psi is required for purpose of input
supply pressure: 250 psi
.
The minimum inlet gas
or any other enclosed area. The maximum inlet gas
installed and must not be stored in a building, garage
disconnected cylinder must have dust caps tightly
well-ventilated area out of the reach of children. A
appliance. A cylinder must be stored outdoors in a
the cylinder is disconnected and removed from the
Storage of an appliance indoors is permissible only if
department should have this book.
Propane Installation Code. Your local library or fire
ANSI/NFPA 58 or CSA B149.1, Natural Gas and
storage and handling of liquefied petroleum gas,
supply system. See chapter 12 of the standard for
Use this heater only with a propane vapor withdrawal
standard 20 lb. propane cylinder only.
propane gas and cylinder are sold separately.Use a
11. Connect hose and regulator to cylinder.The
12
1
12
13
WARNING
After the cylinder is placed inside the heater,
secure the cylinder with block belt tightly.
13. Install wheel kit to base plate by inserting
(2) x Bolt M8 x 15mm through the wheel kit and
base plate and securing them with (2) x Nut M8
(use supplied wrench to tighten).
Hardware Used
Wrench
Qty. 1
OO
Bolt M8 x 15mm
Qty. 2
EE
Nut M8
Qty. 2
HH
Summary of Contents for OH-M744S
Page 18: ...5016039...