background image

 

 

Installing the Outdoor Remote Sensor: 

Note:

 You will need an electric drill for this step.   

  Find an appropriate place for the outdoor remote sensor. 

Note:

 Make sure you install the outdoor remote sensor within a radius of 60 meters from the 

weather station. If there is an obstacle between the outdoor remote sensor and the weather 

station, shorten the distance between the sensor and the weather station according to the 

actual location to prevent the wireless signal from penetrating the obstacle and affecting the 

quality of the data transmission. 

  For wall mounting: 

Hang the outdoor remote sensor with the mount on one screw. 

 

Reception of the Radio signal: 

  The  clock  automatically  starts  the 

DCF

  signal  search  after  7  minutes  of  any  restart  or 

changing of new fresh batteries. The radio mast icon starts to flash. 

  At 1:00 /2:00 / 3:00 am, the clock automatically  carries out the synchronization procedure 

with  the 

DCF

  signal  to  correct  any  deviations  to  the  exact  time.  If  this  synchronization 

attempt  is unsuccessful (the radio mast icon disappears from the display), the system will 
automatically  attempt  another  synchronization  at  the  next  full  one  hour.  This  procedure  is 
repeated automatically up to total 5 times.   

  To  start  manual 

DCF

 

signal  reception,  press  the  “ ”  button  once.  If  no  signals  received 

within  7  minutes,  then  the 

DCF

  signal  search  stops  (the  radio  mast  icon  disappears)  and 

start again at the next full one hour.   

  During RC reception

to stop searching radio signal, 

press the “ ” button once. 

 

F.Y.I.: 

  A flashing radio mast icon indicates that the 

DCF

 signal reception has started 

  A  continuously  displayed  radio  mast  icon  indicates  that  the 

DCF

  signal  was  received 

successfully 

  The symbol "DST" indicating the time of receipt for daylight saving time. 

  We recommend  a  minimum  distance  of  2.5 meters to  all  sources  of  interference,  such as 

televisions or computer monitors 

  Radio  reception  is  weaker  in  rooms  with  concrete  walls  (e.g.:  in  cellars)  and  in  offices.  In 

such extreme circumstances, place the system close to the window. 

  During  the 

DCF

  radio receive  mode, only the 

” button function, other  button 

operation have  no  function,

 

If  you  want  to carry  out  other  functions of  operation, please 

press “ ” button to exit the 

DCF

 radio receive mode. 

 

Summary of Contents for Atlanta EM3333

Page 1: ...AUS oder 5 60min Temperatur alternativ in C oder F Innenraum Temperaturmessbereiche 9 9 C 14 F 50 C 122 F Au entemperatur Messbereiche 40 C 40 F 70 C 158 F Drahtloser Au ensensor o Wandmontage oder T...

Page 2: ...temperatur Die Haupteinheit beginnt nun eine Verbindung mit dem Fernbedienungssensor herzustellen Dieser Vorgang dauert etwa 3 Minuten und wird durch ein blinkendes Empfangs HF Antennensymbol im Anzei...

Page 3: ...rschwindet aus der Anzeige wird zur n chsten vollen Stunde automatisch ein weiterer Synchronisationsversuch unternommen Dieser Vorgang wiederholt sich automatisch bis zu insgesamt 5 Mal Um den manuell...

Page 4: ...d lassen Sie sie wieder los um die Einstellung zu best tigen Das Sommerzeit Symbol blinkt und mit den Tasten und k nnen Sie die Sommerzeit ein oder ausschalten Hinweis Wenn das Sommerzeitsystem in die...

Page 5: ...I DIMANCHE FRE LUN MAR MER JEU VEN SAM DIM ITALIAN LUNEDI MARTED MERCOLED GIOVEDI VENERD SABATO DOMENICA ITA LUN MAR MER GIO VEN SAB DOM SPANISH LUNES MARTES MIERCOLES JUEVES VIERNES SABADO DOMINGO SP...

Page 6: ...er Kraft gesetzt Wenn der Alarm wiederholt sowohl auf M F als auch auf S S eingestellt wird wird die Alarmfunktion die ganze Woche ber aktiviert Dr cken Sie die Taste und lassen Sie sie los um Ihre E...

Page 7: ...rm 2 schalten sich ein das Symbol oder wird angezeigt die Funktion des Alarms 1 oder des Alarms 2 ist ge ffnet das Symbol f r die Wiederholung des Alarms wird ebenfalls angezeigt Der Alarm 1 oder Alar...

Page 8: ...F wird angezeigt wenn der Wert h her als 70 C 158 F ist Temperaturanzeige in C oder F Die Temperatur wird entweder in C oder in F angezeigt Durch kurzes Dr cken der Taste k nnen Sie zwischen den einze...

Page 9: ...den Wecker zu reinigen Copyright Diese Bedienungsanleitung ist geistiges Eigentum der Fa PARAGON Uhren Vertriebs GmbH Ein Kopieren Vervielf ltigen oder Inverkehrbringen insbesondere f r fremde Produkt...

Page 10: ...re alternatively in C or F Indoor Temperature measurement ranges 9 9 C 14 F 50 C 122 F Outdoor Temperature measurement ranges 40 C 40 F 70 C 158 F Wireless Outdoor Sensor o Wall Mount or Table Stand o...

Page 11: ...mode and detect indoor temperature The Main Unit will now start to make a connection to the Remote Sensor This operation takes about 3 minutes and is displayed by a flashing reception RF antenna symb...

Page 12: ...he radio mast icon disappears from the display the system will automatically attempt another synchronization at the next full one hour This procedure is repeated automatically up to total 5 times To s...

Page 13: ...stem is not implemented in this area please set DST to OFF Press and release to confirm your setting the Hour display starts to flash now use and buttons to set the correct hour Note In the set time y...

Page 14: ...ONDAG DUT MAA DIN WOE DON VRI ZAT ZON DANISH MANDAG TIRSDAG ONSDAG TORSDAG FREDAG L RDAG S NDAG DAN MAN TIR ONS TOR FRE LOR SON NORWEGIAN MANDAG TIRSDAG ONSDAG TORSDAG FREDAG L RDAG S NDAG NOR MAN TIR...

Page 15: ...to confirm your setting The Hour display of the Alarm 2 time starts to flash Use the and buttons to set the required hour Press and release button to confirm your setting The Minute display of the Ala...

Page 16: ...ayed if value lower than 9 9 C 14 F HH C F will displayed if value higher than 50 C 122 F Outdoor temperature measuring range 40 C 40 F 70 C 158 F LL C F will displayed if value lower than 40 C 40 F H...

Page 17: ...g instructions are the intellectual property of PARAGON Uhren Vertriebs GmbH Copying duplicating or placing on the market in particular for third party products or purposes is prohibited or only permi...

Page 18: ...F ou 5 60min Temp rature alternativement en C ou en F Plages de mesure de la temp rature int rieure 9 9 C 14 F 50 C 122 F Plages de mesure de la temp rature ext rieure 40 C 70 C Capteur ext rieur sans...

Page 19: ...et d tecte la temp rature interne L unit principale va maintenant commencer se connecter au capteur distance Ce processus dure environ 3 minutes et est indiqu par le clignotement de l ic ne de l ante...

Page 20: ...dispara t de l cran une autre tentative de synchronisation est automatiquement effectu e l heure pleine suivante Ce processus est r p t automatiquement jusqu un total de 5 fois Pour lancer la r ceptio...

Page 21: ...zone veuillez mettre l heure d t sur OFF Appuyez sur et rel chez la touche pour confirmer votre r glage L indicateur d heure se met clignoter utilisez maintenant les boutons et pour r gler l heure co...

Page 22: ...MAA DIN WOE DON VRI ZAT ZON DANISH MANDAG TIRSDAG ONSDAG TORSDAG FREDAG L RDAG S NDAG DAN MAN TIR ONS TOR FRE LOR SON NORWEGIAN MANDAG TIRSDAG ONSDAG TORSDAG FREDAG L RDAG S NDAG NOR MAN TIR ONS TOR F...

Page 23: ...t au long de la semaine Appuyez et rel chez le bouton pour confirmer votre r glage le temps de r p tition de l alarme1 se met clignoter Utilisez les boutons et pour r gler la minute de sieste souhait...

Page 24: ...teindre le signal d alarme Lorsque l alarme retentit appuyez sur n importe quel bouton ou sur la position du caract re SNOOZE et maintenez la enfonc e pendant plus de 2 secondes pour arr ter le signa...

Page 25: ...de port e des jeunes enfants Si une pile est aval e consultez imm diatement un m decin Tenez les enfants loign s des mat riaux d emballage Il y a un risque d touffement entre autres DANGER de blessure...

Page 26: ...ebs GmbH Maybachstr 6 D 71299 Wimsheim Allemagne Retour de batterie Les piles ne doivent pas tre jet es avec les ordures m nag res Le consommateur est l galement oblig de recharger ses batteries Retou...

Page 27: ...of 5 60min Temperatuur naar keuze in C of F Meetbereiken binnentemperatuur 9 9 C 14 F 50 C 122 F Meetbereiken buitentemperatuur 40 C 40 F 70 C 158 F Draadloze buitensensor o Muurbevestiging of tafelst...

Page 28: ...ert de interne temperatuur Het hoofdtoestel begint nu verbinding te maken met de draadloze sensor Dit proces duurt ongeveer 3 minuten en wordt aangegeven door een knipperend ontvangst RF antenne icoon...

Page 29: ...ool verdwijnt van het display wordt automatisch een nieuwe synchronisatiepoging ondernomen op het volgende hele uur Dit proces wordt automatisch herhaald tot een totaal van 5 keer Om de handmatige DCF...

Page 30: ...ied niet is ge mplementeerd zet u de zomertijd op UIT Druk op en laat de knop los om uw instelling te bevestigen De urenindicator begint te knipperen gebruik nu de en toetsen om het juiste uur in te s...

Page 31: ...WOE DON VRI ZAT ZON DANISH MANDAG TIRSDAG ONSDAG TORSDAG FREDAG L RDAG S NDAG DAN MAN TIR ONS TOR FRE LOR SON NORWEGIAN MANDAG TIRSDAG ONSDAG TORSDAG FREDAG L RDAG S NDAG NOR MAN TIR ONS TOR FRE LOR S...

Page 32: ...steld zal de alarmfunctie gedurende de hele week worden geactiveerd Druk kort op de toets om uw instelling te bevestigen de snoozetijd van alarm1 begint te knipperen Gebruik de knoppen en om de gewens...

Page 33: ...kt Uitschakelen van het alarmsignaal Wanneer het alarm afgaat drukt u op een willekeurige toets of raakt u de SNOOZE tekenpositie aan en houdt u deze langer dan 2 seconden ingedrukt om het alarmsignaa...

Page 34: ...slikt Houd daarom de batterij en de wekker buiten het bereik van kleine kinderen Als een batterij wordt ingeslikt moet onmiddellijk medische hulp worden ingeroepen Houd kinderen uit de buurt van verpa...

Page 35: ...n Vertriebs GmbH Maybachstr 6 71299 Wimsheim Duitsland accu retour Batterijen mogen niet worden afgevoerd met het huishoudelijk afval De consument is wettelijk verplicht batterijen na gebruik terug vo...