19
LT5245 (2:02/09)
Paragon Symphony CF
Maintenance Instructions
SECTION ELEVEN
Maintenance Continued
REPLACEMENT OF OXY-PILOT ASSEMBLY
NOTE:
If the pilot assembly is replaced it must be replaced by an identical unit from the same
manufacturer and replaced as a complete unit.
•
Follow the burner tray removal sequence.
•
Undo the compression nut on the supply pipe at the pilot.
•
Carefully pull off the ignition lead.
•
Disconnect the thermocouple at the end of the main control valve.
•
Remove the cross headed nut holding the pilot to the chassis
•
Carefully remove the pilot shield & oxy-pilot.
•
Re-assemble in reverse order.
REPLACEMENT OF CONTROL UNIT (EDB)
•
Follow the burner tray removal sequence.
•
Disconnect leads from control unit and remove 4 bolts.
•
Re-assemble in the reverse order.
Turn on the gas supply, check for gas soundness and re-commission appliance.
FLUE CHECK
•
Remove the fire from the opening: - Reversing fitting instructions, but first remove fascia,trim,
glass panel and Log shapes.
•
Examine flue and rectify as necessary.
•
Replace the fire, referring to fitting instructions.
SECTION TWELVENE
Wiring Diagram
Summary of Contents for SYMPHONY CF