www.parametric.ch/product/pcr2-ods
02 Error LED
After pressing the user button, the Error LED is only ON if there is a serious hardware
problem with the battery or charger.
LED Status
Description
OFF
No Error
Blinking 1x
Battery Not Connected
Blinking 2x
Battery Too Cold
Blinking 3x
Battery Too Hot
Blinking 4x
Battery Voltage Too Low. Initial Charging Is Active
03 Charging LED
The Charging LED is always activated.
LED Status
Description
OFF
No Power Input
ON
Power Source Input
Blinking
Charging Active
Installation
•
PCR2-ODS are shipped with a
disconnected battery for safety
reasons.
Connect the battery pack
cable to the circuit board
.
•
If the battery LED blinks rapidly, the
battery voltage is too low to turn on
the PCR2-ODS sensor. This is to
avoid a deep discharge of the
battery.
•
We recommend you pre-charge the
battery using the included USB
charging adapter.
•
Charge the battery until the voltage
is sufficiently high and the PCR2-
ODS will turn on.
•
Check for the two direction PCR2-
ODS LEDs under the lid to turn on.
Both LEDs blink while the device
connects to the LPWAN.
•
Fix the solar panel bracket to the
back of the solar panel using the
provided flat washers and nuts.