5.3.4.
P00 - User Menu
The User menu shows normal operational values and information displays. This is the default display menu; no
access code is required.
item
description
units
step
min
max
display*
1
Compressor status
---
no_edit
---
---
S>
Semi Automatic mode
F>
Fully Automatic mode
TS
Safety valve test
TL
Leakage test
TO
Output test
2
Cabinet temp
°C/°F
no_edit
---
---
T2
100
0
C
3**
3rd stage press
bar/psi
no_edit
---
---
P2
50 bar
4
Delivery press
bar/psi
no_edit
---
---
Pd
270 bar
5
Hours Run
H
no_edit
---
---
H1
0 hrs
6
Oil service hrs
H
no_edit
---
---
H2
500 hrs
7
BA filter service hrs
H
no_edit
---
---
H3
500 hrs
* All values shown in display column are ONLY examples.
** Only shown if enabled
Status Information Item:
The page 0 ‘Status Information Item’ provides a basic overview of status using symbols. Press the ‘C’ button at any
time while in normal operation, menu P00, to view this menu item.
The mode of operation is displayed as the status information item identifier:
S>
Semi Automatic Mode (normal operational mode)
F>
Fully Automatic Mode (normal operational mode)
TS
Safety valve test (test mode)
TL
Leakage test (test mode)
5.3.5.
P01 - Operation Menu
Contains general operation parameters that may be modified by the User from time to time.
item
description
units
step
min
max
display*
1
Compressor mode
0/1
1
0
1
0 =>
M> S
(Semi)
1 =>
M> F
(Full)
2
unload pressure**
bar/psi
1
0.1
55.0
5.5
390.0
59.0
Pu 225 bar
3
load pressure**
bar/psi
1
0.1
50
5.0
385.0
58.5
PL 215 bar
4
cutout pressure
bar/psi
1
0.1
55.0
5.0
390.0
59.0
Pc 235 bar
5
Drain open time before start
s
1
1
10
db
8 s
6
Drain open time after start
s
1
1
10
dA
6 s
7
Drain exhaust time
s
1
1
20
dE
10 s
8
Drain 1 open time
s
1
1
5
d1
3 s
9
Drain 1 interval time
m
1
1
20
d1
4 m
10
Drain 2 open time
s
1
1
5
d2
3 s
11
Drain 2 interval time
m
1
1
20
d2
4 m
12
Drain 3 open time
s
1
1
5
d3
3 s
13
Drain 3 interval time
m
1
1
20
d3
4 m
14
pressure
units
0=bar
1=psi
2=kPA
1
0
2
P>
0
15
temperature
units
0
=
0
C
1=
0
F
1
0
1
T>
0