User Manual -
Cyclone Silent -
1-2018 edition
PARAMINA SA – Byway Evaggelistrias str. 19300 Aspropirgos, Greece, Tel: 0030 210 5575860-1
Fax: 0030 210 5575868, email:
service@paramina.gr
- website:
www.paramina-compressors.com
27
SERIAL NUMBERS TILL 31/12/2010
5.5.
Immediate Stop Shutdown Errors
5.5.1
Digital input errors
Er:0010 E
Emergency stop
Er:0020 E
1
st
stage OR 2
nd
pressure switch. Pressure high or switch fault.
Er:0070 E
main motor or fan motor overload. Thermal switch enabled.
Er:0080 E
safety pressure switch – 3
rd
stage trip
5.5.2
Analog input errors
Er:0115 E
delivery pressure (4
th
stage) sensor fault
Er:0119 E
delivery pressure (4
th
stage) high
Er:0125 E
temperature (4
th
stage) sensor fault
Er:0129 E
temperature (4
th
stage) high
5.6
Controlled Stop Shutdown Errors
5.6.1
Special function service trips
Er:1814 E
OIL service due trip
Er:1824 E
final BA FILTER service due trip
Er:0821 E
low resistance, short circuit or short circuit to earth condition exists on an
analogue input or digital input (incorrect connection, cable fault or sensor fault)
5.7
Alarms
5.7.1
Analogue input alarms
Er:2118 A
delivery pressure (4
th
stage) high
Er:2128 A
temperature (4
th
stage) high
5.7.2
Special function alarms
Er:2816 A
power failure while compressor was in started state
5.8
Start Inhibits
Er:3123 S
Temperature (4
th
stage) below the set low temperature run inhibit level, controller will allow
motor start when temperature increases above the preset level
5.9
Special function service alarms
Er:4814 A
OIL service due alarm
Er:4824 A
final BA FILTER due alarm