1.
Unscrew the filter head counter clockwise.
2.
Remove the filter head.
3.
Place the
special handle
on top of the A.C.-M.S cartridges.
4.
Remove the A.C.-M.S. cartridges by pulling upwards with the
special handle.
Before throwing away the
used cartridges, do not forget to remove the cartridge connector.
5.
Clean the inside of the filter housing with a clean cloth.
6.
Remove the new A.C.-M.S. cartridges from their protective case. Be sure that packaging is not punctured.
If it is damaged do not use it.
7.
Lay a small amount of silicone grease on the o-ring of the new A.C.-M.S. cartridge.
8.
Screw the two A.C.-M.S. cartridges together so as to create a solid body.
9.
Replace the two o-rings of the cartridge connector, lay a small amount of silicone grease on the new o-
rings and then screw the connector on the bottom A.C.-M.S. cartridge.
10.
Place the new A.C.-M.S. cartridges in the filter housing and fasten it down by hand on the coalescing
connector (see also drawing nr. B).
11.
Lay a small amount of silicone grease on the o-rings of the filter head. If there is a trace of damage on the
o-rings, replace.
12.
Screw the filter head carefully by hand with light pressure until it fits evenly to the filter housing.
Do not screw really tight, while screwing cartridges or connectors inside filter’s housing.
FILTER HEAD & FILTER HOUSING SHOULD BE ADJOINED ON TOP WHEN REINSTALLING.
Replacement of coalescing cartridge & active carbon – molecular sieve cartridge
1.
Unscrew the filter head counter clockwise.
2.
Remove the filter head.