Replacement of coalescing cartridge & active carbon – molecular sieve cartridge
1.
Unscrew the filter housing by hand and remove it from its base.
2.
Unscrew the A.C.-M.S. cartridges along with their connector (cartridge connector) from the tube
connector.
3.
Remove the coalescing cartridge & cover from the filter’s base by pulling upwards.
4.
Lay a small amount of silicone grease on the o-ring of the filter’s base. If there is a trace of damage on the
o-ring, replace.
5.
Install the new coalescing cartridge & cover on filter’s base by fastening it down with your hand.
6.
Wrap a small amount of Teflon around the thread of the tube connector.
7.
Screw the cartridge connector on the tube connector (on top of the coalescing cartridge).
8.
Remove the new A.C.-M.S. cartridges from their protective cases. If the packaging is damaged or
punctured do not use it.
9.
Lay a small amount of silicone grease on the o-rings of the new A.C.-M.S. cartridges.
10.
Screw the two A.C.-M.S. cartridges together so as to create a solid body.
11.
Screw the new cartridges on the cartridge connector.
12.
Clean the inside of the filter housing with a clean cloth.
13.
Screw the filter housing carefully until securely fastened onto the base.