Paramount 755T/785T Owner’s Manual
31
Set New Calibration Distance
1.
To set a new calibration distance select
Yes
.
2.
Remove the top motor cover and make a visible mark on the flywheel next to a
consistent reference point.
3.
Place a piece of tape near the front of the treadmill belt with another piece of
tape on a stationary section of the frame next to it.
4.
Place a mark on both pieces of tape with the marks lined up with each other
when the mark on the flywheel is at its reference point.
5.
Manually rotate the flywheel in the direction of normal rotation (so the tape on
the belt is moving toward the back of the treadmill) 10 full rotations stopping
when the mark on the flywheel aligns with the reference point.
6.
Measure the distance from the stationary mark on the frame of the treadmill to
the now moved mark on the tape on the walking belt.
7.
Input that distance in inches (or cm) when “Input measured distance in inches”
appears.
8.
Press
Enter
to accept and move to the next screen.