'99+3(2?
7.
While supporting heater, tilt the head assembly (C) and slide the assembled
reflector over the 3 bolts that extend from the head assembly. Use
3 M8 wing nuts and 3 M8 washers to secure the assembled reflector to the
head assembly of the heater. Once you have tightened the wing nuts, return
the heater to an upright position.
8.
Connect the hose and regulator (from the natural gas company) to the
natural gas outlet. The natural gas is obtained from your natural gas
supply company. Use a standard 7” WC natural gas only.
NOTE: Use this heater only with natural gas supply system. See chapter 5
of the standard for storage and handling of liquefied petroleum gas, ANSI/NFPA 58.
Your local library or fire department should have this book.
7
8
Hardware Used:
3 - M8 wing nuts
3 - M8 Washers