background image

 

14 

 

 
 
After Operation

1. Gas control knob is in OFF position. 
2. Gas tank valve is OFF. 
3. Disconnect gas line.

 

 
 
 
 
 
 
 
 
 
 

To enjoy years of outstanding performance from your heater, make sure you perform the following maintenance 
activities on a regular basis: 

Keep exterior surfaces clean

1. Use soapy water for cleaning. Never use flammable or corrosive cleaning agents. 
2. While cleaning your unit, be sure to keep the area around the burner and control compartment dry at all times. 
Do not submerge the control valve assembly. If the gas control is submerged in water, do NOT use it. It must be 
replaced. 
3. Air flow must be unobstructed. Keep controls, burner, and circulating air passageways clean. Signs of possible 
blockage include: 

 

Gas odor with extreme yellow tipping of flame. 

 

Heater does NOT reach the desired temperature. 

 

Heater glow is excessively uneven. 

 

Heater makes popping noise. 

 

Spiders  and  insects  can  nest  in  burner  or  orifices.  This  dangerous  condition  can  damage  heater  and 
render it unsafe for use. Clean burner holes by using a heavy-duty pipe cleaner. Compressed air may help 
clear away smaller particles. 

 

Carbon deposits may create a fire hazard. Clean dome and burner screen with warm soapy water if any 
carbon deposits develop. Always be careful when cleaning the glass tube. 

 
Note

: In a salt-air environment (such as near an ocean), corrosion occurs more quickly than normal. Frequently 

check for corroded areas and repair them promptly. 

 
 
Storage

Between uses: 

 

Turn control knob OFF. 

 

Disconnect LP source. 

 

Store heater upright in an area sheltered from direct contact with inclement weather (such as rain, sleet, 
hail, snow, dust and debris). 

 

If desired, cover heater to protect exterior surfaces and to help prevent build-up in air passages. Never 
leave LP cylinder exposed to direct sunlight or excessive heat. 

               

Note

: Wait until heater is completely cool before covering

 

 
Service

Only a qualified service person should repair gas passages and associated components. 
 

Caution

: Always allow heater to cool before attempting service. 

 
 
 
 

 
 
 

                                                                         

CARE AND MAINTENANCE 

 

Summary of Contents for LIP-09A-TGG

Page 1: ...ctions in this manual could result in bodily injury and or property damage PRECAUTIONS vapours and liquids in the vicinity of this or any other appliance Any LP cylinder not connected for use shall no...

Page 2: ...urned off and removed NOTE Use only 20lb LP Gas tank with size of 18 1in 46cm Height 12 5in 32cm Width Do not use if the environment temperature is below 40 degrees F 4 4 degrees C WARNING Improper in...

Page 3: ...o use check for damaged parts such as hoses regulators pilot or burner Turn off and disconnect LPG cylinder before moving the heater Do not attempt to alter this heater in any manner EXAMPLE Using the...

Page 4: ...r to operating the heater Installation and repair should be done by a qualified service person The heater should be inspected before use and cleaning may be required at least once a year or as necessa...

Page 5: ...Cap 1 A Reflector 1 B Emitter 1 C Upper Supports 4 D Lower Supports 4 E Mesh Guards 8 F Glass Tube Connector 1 G Glass Tube 2 pcs H Burner 1 I Tank Housing Base Assembly with wheels 1 J Regulator Hose...

Page 6: ...customer service for replacement parts ESTIMATE D ASSEMBLY TIME 60 minutes Tools Required for Assembly NOT included Phillips screwdriver w medium blade Leak Test Solution Adjustable wrench Note 14mm w...

Page 7: ...e Used 4 x D Mesh Guard Connector 2 Attach the assembled Supports to the Tank Housing Base Assembly Screw the assembled Supports into the holes located on the top of the Tank Housing Base Assembly Not...

Page 8: ...upports by lining up the holes in the corners of the Emitter with the Supports and sliding the Emitter down over the Supports 4 Secure the Emitter to the Supports using 4 pieces of B M8 Spacer Tighten...

Page 9: ...8 Nut 8 Assemble Glass Tube Locate Glass Tube Connector F and 7 Place Top Cap L into Reflector two pieces of Glass Tube G Carefully insert one end of Glass Tube Connector into open end of Glass Tube a...

Page 10: ...er piece pre assembled on the Emitter see Fig A 11 Before placing LP tank onto base of heater attach Cylinder Holder K to base using 3 pieces of M6x12 Bolts Hardware Used 3 x C M6x12 Bolt Connect the...

Page 11: ...g prevention device The cylinder must have a connection device compatible with the connection for the appliance The cylinder used must include a collar to protect the cylinder valve Never connect an u...

Page 12: ...e person at least annually If re lighting a hot heater always wait at least 5 minutes 2 Inspect the hose assembly for evidence of excessive abrasion cuts or wear Suspected areas should be leak tested...

Page 13: ...mph 6 Unit will operate at reduced efficiency below 40 degrees F 7 Heater is for use outdoors outside any enclosure 8 There is adequate fresh air ventilation 9 Heater is away from gasoline or other fl...

Page 14: ...ces This dangerous condition can damage heater and render it unsafe for use Clean burner holes by using a heavy duty pipe cleaner Compressed air may help clear away smaller particles Carbon deposits m...

Page 15: ...ressure low with valve open full Replace cylinder or regulator New cylinder or 1st ignition Purge air from lines Cylinder valve on no gas flow Replace hose regulator assembly AAA Battery behind ignite...

Page 16: ...service please call our toll free number 1 800 561 5550 Customer Service JR Home Products Unit 1 5628 Riverbend Drive Burnaby BC V3N 0C1 Toll Free 1 800 561 5550 E mail customercare jrhome com Warrant...

Reviews: