H.
Attach the guard bar to the heating
furnace using the clawscrew(M6X12mm).
Install a full gas cylinder
on the base. Connect
the gas regulator hose to the cylinder valve by
turning the knob clockwise manually . do not
use a tool. Tighten firmly by hand
.
Close door
.
LEAK TEST
Now that the heater is assembled, for your safety you must perform a leak test of all
connections and hoses.
Mix in a spray bottle equal parts of water and soap.
1. Ensure that the heater gas control knob is fully closed by turning
completely clockwise
2. Open cylinder valve.
3. Apply the solution generously to all connections and hoses.
If you detect bubbles, there is a leak. Close cylinder valve completely. Retighten the
leaking connection and repeat leak test process.
If the leak cannot be repaired permanently, close cylinder valve completely and contact
a qualified gas technician.
I.
ASSEMBLY AND INSTRUCTIONS
8