background image

CLEANING AND MAINTENANCE:

Storage between usage:

During periods of extended inactivity or when transporting:

CLEANING/MAINTENANCE/STORAGE

● 

● 

● 

● 

●  

●  

●  

●  

● 

●  

●  

●  

●     

- 11 -

To enjoy outstanding performance of your heater for years make sure to perform the 

following maintenance activities on a regular basis:

Keep exterior surfaces clean.

-Use warm soapy water for cleaning. Never use flammable, corrosive or abrasive 

cleaners.

-While washing your unit, be sure to keep the area around the burner and pilot assembly 

dry at all time. If the gas control is exposed to water in any way, do NOT try to use it. It 

must be replaced.

After a long break from operation, the unit should be inspected for spiders, spider webs 

or other insects.

Air flow must be unobstructed. Keep controls. Burner and circulating air passageways 

clean.

Signs of possible blockage include:

-Gas odor with extreme yellow tipping of flame.

-Heater does NOT reach the desired temperature.

-Heater glow is excessively uneven.

-Heater makes popping noises.

Spider and insects can nest in burner or orifices.

This dangerous condition can damage heater and render it unsafe for use. Clean burner 

holes by using a heavy-duty pipe cleaner.

Compressed air may help clear away smaller particles.

Carbon deposits may create a fire hazard. Clean reflector and glass tube inside abo with 

soapy water if any carbon deposits develop. Always be careful when cleaning the glass 

tube.

Turn the control knob to “OFF” position.

Take cylinder out of product. 

Store heater upright in an area sheltered away from weather conditions (such as rain, 

sleet, hail, snow).

if desired, cover heater to protect exterior surfaces and to help prevent dust and debris 

collecting in air passages.

Turn the control knob to “OFF” position.

Disconnect LP Cylinder and move to a secure, well-ventilated location outdoors.

DO NOT store in a location that will exceed 50 degrees C.

Store heater upright in an area sheltered away from weather conditions (such as rain, 

sleet, hail, snow).

If desired, cover heater to protect exterior surfaces and to help prevent dust and debris 

collecting in air passages.

  

Summary of Contents for PH05-S

Page 1: ...cylinder or regulator Extinguish all naked flames do not operate any electrical appliances Check for leaks as detailed in this instructions If odor persists contact your dealer or gas supplier immedi...

Page 2: ...e instructions thoroughly before installing or servicing this equipment WARNING FOR OUTDOOR USE ONLY Cylinders to be used must be constructed And marked in accordance with US DOT speci cations Storage...

Page 3: ...t is raining and do not let any liquid splash to the glass tube when the heater is working Keep the children away from the heater always be carefully not to knock down the heater which will break the...

Page 4: ...cylinder housing Shut off the valve of gas cylinder or the regulator before moving the appliance The tubing or the flexible hose must be changed within the prescribed intervals Use only the type of g...

Page 5: ...OF OUTDOOR AREAS APPLIANCE STAND AND LOACTION The appliance is for outdoor use only Do not use it for indoor or in an enclosed area Always maintain proper clearance from combustible materials i e top...

Page 6: ...y leaking fitting carefully turn gas again and recheck Never leak test while smoking INSTALLATION Important safety requirements THIS APPLIANCE OUTDOOR USE ONLY 1 This appliance shall not be installed...

Page 7: ...s Bottom Plate Control Box Middle Plate Support Upper Plate Plate cover Glass tube Damper Reflector 1 1 1 4 1 1 1 1 1 1 2 3 5 6 7 8 9 10 Preassembled in the Middle plate Preassembled in the Middle pla...

Page 8: ...stening Side panel Front panel Screw M4 Knob Nuts AA battery 3 8 4 4 3 1 66 1 1 1 11 12 13 14 15 16 17 18 19 20 Connect with damper and reflector A chain is preassembled in this panel All preassembled...

Page 9: ...reflector into the frame parts using two side bolts then use the nuts to firm the top 2 Using wing nuts to firm the reflector completely 9 INJECTOR 3 Inner regulator is stored inside Pl connect the r...

Page 10: ...he ignition chamber and has power Ensure The anode faces outside Ensure that the control knob is OFF Slowly open the gas cylinder valve Press and turn the control knob to LIGHT position push the ignit...

Page 11: ...sively uneven Heater makes popping noises Spider and insects can nest in burner or orifices This dangerous condition can damage heater and render it unsafe for use Clean burner holes by using a heavy...

Page 12: ...an or replace Orifice Purge air from lines Check all fittings Clean dirty area Tighten connection Replace Thermocouple Check connections Fuel tank is near empty Fuel tank is near empty Remove clean an...

Page 13: ...service please call our toll free number 1 800 561 5550 Customer Service JR Home Products Unit 1 5628 Riverbend Drive Burnaby BC V3N 0C1 Toll Free 1 800 561 5550 E mail customercare jrhome com Warrant...