LEAKAGE TEST
Gas connections on the appliance are leak tested at the factory prior to shipment. Possible
mishandling of the appliance during the shipment might contribute to product integrity as a
whole. A complete gas leakage test must be performed again at the installation site. Please
follow the procedure below for leakage test.
- Make a soap solution of one part liquid detergent and one part water. The soap solution can
be applied with spray bottle, brush or rag. Soap bubbles will appear where a leak is present.
- Make sure the control tap is in the “OFF” position (full disk = ●) on the control panel.
- Turn on the gas supply and check for bubbles from the hoses and connections. Presents of
bubble means that a leak path is present.
- If a leak is present, turn OFF the gas supply immediately, tighten any leaking fitting carefully,
turn gas again and recheck.
- Never leak test while smoking.
INSTALLATION
Important safety requirements:
THIS APPLIANCE OUTDOOR USE ONLY
1. This appliance shall not be installed or used indoors, in buildings, garages or any other
enclosed area.
2.
DO NOT
place articles on or against this appliance.
3.
DO NOT
use or store flammable materials near this appliance.
4.
DO NOT
operate this appliance unless it is fully assembled with reflector and protection
guard in place.
5. Installation and repair should be done by a qualified service person. The appliance must
be inspected before use and at least annually by a qualified service person. More frequent
cleaning may be required as necessary. It is imperative that control compartment, burners
and circulating air passages of the heater and light be kept clean.
6. Please use the pressure regulator and hose assembly supplied with the heater, the
replacement pressure regulator and hose assemblies must be according to ANSI/UL 144.
- 6 -