4
POND SIzINg CHART
See Chart Below.
ULTRA UV Part Number
Maximum
Flow
Rate
(GPM)
Maximum
Flow
Rate
(m3/hr)
Max
Pond
Volume
2 Hr.
Turnover
(GPM)
Max
Pond
Volume
2 Hr.
Turnover
(m3)
Max
Pond
Volume
3 Hr.
Turnover
(GPM)
Max
Pond
Volume
3 Hr.
Turnover
(m3)
004-422-2025-00 230V w/ 1 UV-C Lamp
004-422-2029-40 2 30V w/ 1 UV-C Lamp
w/SS Reactor
004-422-2021-00 120V w/ 1 UV-C Lamp
004-422-2029-00 1 20V w/ 1 UV-C Lamp
w/SS Reactor
46
10.4
5520
20.9
8280
31.3
004-422-2026-00 230V w/ 2 UV-C Lamps
004-422-2029-50 2 30V w/ 2 UV-C Lamps
w/SS Reactor
004-422-2022-00 120V w/ 2 UV-C Lamps
004-422-2029-10 1 20V w/ 2 UV-C Lamps
w/SS Reactor
80
18.2
9600
36.3
14400
54.5
004-422-2027-00 230V w/ 3 UV-C Lamps
004-422-2029-60 2 30V w/ 3 UV-C Lamps
w/SS Reactor
004-422-2023-00 120V w/ 3 UV-C Lamps
004-422-2029-20 1 20V w/ 3 UV-C Lamps
w/SS Reactor
130
29.5
15600
59.1
23400
88.6
004-422-2028-00 230V w/ 4 UV-C Lamps
004-422-2029-40 2 30V w/ 4 UV-C Lamps
w/SS Reactor
004-422-2024-00 120V w/ 4 UV-C Lamps
004-422-2029-30 1 20V w/ 4 UV-C Lamps
w/SS Reactor
164
37.2
19680
74.5
29520
111.7
All capacities are nominal. Note: Multiple ULTRA UV units can be used for flow
rates beyond those specified herein. (See page 7, Fig. 2a)