9
ELECTRICAL BONDINg (gROUNDINg)
Locate the grounding lug next to the
power cable (Fig. 4). To reduce the risk
of electric shock, this terminal must
be connected to the grounding means
provided in the electrical supply service
panel with a continuous copper wire
equivalent in size to the circuit conductors
supplying this equipment. To reduce the
risk of electric shock, connect the local
common bond grid in the area of the pool or spa to this terminal with
an insulated or bare copper conductor not smaller than 6 AWG. The
electrical installation is now complete.
DANgER - RISK OF ELECTRICAL SHOCK - RISK OF
INJURY OR DEATH IF ELECTRICAL INSTALLATION IS
NOT DONE PROPERLY.
Paramount Recommends you have this important work done by a Licensed
Electrical Technician!
PRESSURE SWITCH
The ULTRA UV unit is equipped
with a pressure switch that does
not allow the UV lamp(s) inside the
unit to light unless there is at least 5
PSI (0.35 Bar) inside the ULTRA UV
reactor chamber. This will ensure that
the lamp(s) will not illuminate when
the ULTRA UV unit does not have
water flowing through the reactor
or if it is empty. The lamps will only
illuminate when the pressure switch
senses a minimum of 5 psi (0.35 bar). NOTE: If the top of the unit is installed
below water level a flow switch must be installed in the outlet line. NOTE:
The ULTRA UV unit comes with the pressure switch disabled. It must be
connected at startup (not before) for the unit to work. (Always turn off power
to the unit before doing any work on it.)
Fig. 4
grounding Lug
Fig. 5