background image

REAR PANEL CONNECTIONS AND CONTROLS continued

Correct Speaker Polarity is Important

As you connect the speaker wires, you can see that the insulation on one of the two wires in 
each pair has either printing or a raised ridge. The marking lets you know which wire you con-
nected to the positive speaker terminal at its other end.
Make sure the + wire you attach to each Model 275 + speaker terminal is attached to the 
+ terminal of the speaker for that channel.

Bridging Switch: Stereo - Mono 

The Model 275 power should always be turned off before moving this switch.
For normal operation the Bridging switch must be set to Stereo.
For bridged mono operation, set it to Mono.

Note: 

Stereo sound will be faint and very distorted if you accidentally leave the Bridging switch 

in its Mono position.

  

Mono Operation

We recommend an 8 ohm minimum speaker load for bridged mono opera-
tion. For mono the Model 275 “bridges” the R channel to amplify only the 
positive half of the audio signal and the L channel to amplify only the nega-
tive half of the audio signal. In effect, each channel “sees” only half of the 
speaker’s rated impedance, so that an 8 ohm speaker in bridged mono is 
only a 4 ohm load and a 4 ohm speaker in mono is only a 2 ohm load. This 
is why the mono power output is much higher than the sum of the L and R 
channel outputs for stereo operation.

Mono Input and Speaker Connections

1.   Turn the unit off and remove the AC cord.
2.   Connect the single cable from the preamp or controller to the R channel Input jack.
3.   Set the Bridging switch to its Mono position.
4.   Connect the positive lead of the speaker wire to the red R + channel speaker pair A terminal.
5.   Connect the negative lead of the speaker wire to the red L + channel speaker pair A terminal.
6.   Do not connect anything to either the L - or R - speaker terminals.
7.   If you have a second mono speaker repeat steps 4 - 6 with the speaker pair B terminals
8.   Reconnect the AC cord.

Note: 

The Model 275 creates more heat when it drives a bridged mono speaker or multiple 

speaker pairs. Lower impedance speakers will make it run even hotter. Heat greatly reduces 
the life of the amplifier and nearby components. Please heed the instructions for setting the 
Load Impedance switch to avoid overheating.

Load Impedance Switch

6

WARNING: To Prevent Fire Or Shock Hazard,

Do Not Expose This Unit To Rain Or Moisture.

AC      115V/60Hz

AC      230V/50Hz

Speaker Pair A

L

R

Mono

Manual

Audio Sens

Max Min

12V Trigger

Ground

Lift Norm

Mono

Stereo

4-8

Ohms

2-3 

Ohms

230V

50Hz

115V

60Hz

20Hz 40Hz

Flat

Audio

Auto Turn On

Loop

Level

Bridging

In

12V

In

Loop

R

Mono

+

+

AC      115V/60Hz

AC      230V/50Hz

Power Consumption: 300W

AC

Voltage

Load

Impedance

275 Two Channel Amplifier

Parasound Products, Inc.

San Francisco, CA    U S A

CAUTION: To Prevent Electric Shock, Do Not Remove Cover. No 

User-Serviceable Parts Inside. Refer Servicing To Qualified Service Personnel.

L

High Pass Filter

Speaker Pair B

L

R

Mono

WARNING: To Prevent Fire Or Shock Hazard,

Do Not Expose This Unit To Rain Or Moisture.

AC      115V/60Hz

AC      230V/50Hz

Speaker Pair A

L

R

Mono

Manual

Audio Sens

Max Min

12V Trigger

Ground

Lift Norm

Mono

Stereo

4-8

Ohms

2-3 

Ohms

230V

50Hz

115V

60Hz

20Hz 40Hz

Flat

Audio

Auto Turn On

Loop

Level

Bridging

In

12V

In

Loop

R

Mono

+

+

AC      115V/60Hz

AC      230V/50Hz

Power Consumption: 300W

AC

Voltage

Load

Impedance

275 Two Channel Amplifier

Parasound Products, Inc.

San Francisco, CA    U S A

CAUTION: To Prevent Electric Shock, Do Not Remove Cover. No 

User-Serviceable Parts Inside. Refer Servicing To Qualified Service Personnel.

L

High Pass Filter

Speaker Pair B

L

R

Mono

Summary of Contents for 275

Page 1: ...Model 275 Two Channel Power Amplifier OWNER S GUIDE Model 275 Two Channel Amplifier A B Power M o d e l 2 7 5 T w o C h a n n e l A m p l i f i e r Protect Hi Temp L R...

Page 2: ...will only fit into a grounding power outlet If you are unable to insert the plug into the outlet contact your electrician to replace your obsolete outlet Do not defeat the safety purpose of the ground...

Page 3: ...High Pass Filter Switch 4 Speaker Connections 5 Bridging Switch Stereo Mono 5 Mono Input 6 Speaker Connections 6 Load Impedance Switch 6 Auto Turn On 6 Sensitivity Adjust Knob 8 Ground Switch 8 Front...

Page 4: ...thoroughly before you begin installation Unpacking Carefully unpack your Model 275 and these accessories Detachable AC power cord Trigger wire with a 2 5 mm sub mini plug at both ends Trigger wire ad...

Page 5: ...till develop around any heat producing equipment Therefore a ventilation fan is high ly recommended Allow a few inches of empty space on each side and above the unit and try to avoid crowding or stack...

Page 6: ...certified amplifier might play a bit louder because of its higher power output We recommend setting the 275 s R and L level controls to 3 o clock if you are driving it from a THX surround controller...

Page 7: ...peakers is another way the 275 will run cooler Note Autoformer type passive volume controls are highly reactive loads that are known to cause amplifier malfunction The 20 Hz or 40 Hz filter settings e...

Page 8: ...the mono power output is much higher than the sum of the L and R channel outputs for stereo operation Mono Input and Speaker Connections 1 Turn the unit off and remove the AC cord 2 Connect the single...

Page 9: ...s set to its 12V position the Model 275 is turned on and off with an external 9V to 12V voltage from your preamp or controller When the external volt age ceases the Model 275 will turn off immediately...

Page 10: ...gging in the 275 s AC cord for the first time will usually create an internal power surge that false triggers its Audio auto turn on even if there s no audio signal at its input jacks and it will rema...

Page 11: ...right away You can also turn it off by unplugging its AC power cord Auto Turn On switch in the Audio position turn off the preamplifier surround controller or system controller that drives your 275 Y...

Page 12: ...ires are secure at both ends Make sure the control preamp receiver is switched to the correct input If using Auto turn on increase the sensitivity of the audio trigger Is the Hi Temp or Protect or bot...

Page 13: ...Dealer or Parasound Authorized Reseller Units Will Be Refused by Parasound Under the Following Conditions 1 Unit was sent without the Parasound assigned RA number marked on the carton 2 Unit was sent...

Page 14: ...at 2 828 V output IHF A weighted 84 dB at 2 828 V output unweighted Input Impedance 33 k Input Sensitivity 800 mV for full rated output Inter Channel Crosstalk 80 dB 1 kHz 72 dB 10 kHz 65 dB 20 kHz D...

Page 15: ...Notes CONNECTION AND SETUP NOTES 13...

Page 16: ...why Parasound has been a quality and value favorite of magazine reviewers sound professionals and listeners like you since we were founded in 1981 rev 0 91 2005 Parasound Products Inc Parasound Produ...

Reviews: