background image

                                                            

 

 

RESCUE GUARDIAN 

 Switch Functionality 

 

 

 

 

Activity  

Push button 1 (SELECT) Black 

Push button 2 (ARM / DISARM) Red 

Press Momentarily 

 

Button 1 and Button 2  

 

Power ON  

Press and Hold 5 seconds 
(Button 1 and Button 2 
Simultaneous) 

Power OFF 

Press and Hold 5 seconds 

Turn on/off Display Front Light 

Load Alarm  
SET & RESET* 

Press Once Momentarily  

When display ON: Toggle Between 
Load Units and Incline 
When Display OFF: Wake up Display 

No Functionality 

 

Self-Calibration on Start up  

Install charged batteries and secure the battery compartment lid of the Rescue Guardian. Place 
the Rescue Guardian on a Flat surface and depress both Pushbuttons quickly and simultaneously. 
The Rescue Guardian will enter a 

“self

-

calibration” mode so it is imperative to NOT to move the 

unit for approximately 10 seconds as it powers up.  

 

Threshold Settings  

Definition

 - 

The point at which a sensor reading exceeds the minimum or maximum parameters 

entered by the user triggering the Alarm Condition.  

 

 

Load 

 

(Selectable Units) 

Incline Angle

 

(Degrees) 

Vibration 

 

(Hertz) 

Pounds  

Min 100 - Max 2300 

Min 0.1 

 Max 15 

1hz 

 100hz 

Kilograms 

Min 45 -   Max 1043 

 

 

Newtons  

Min 444 - Max 10230 

 

 

*Default ALARM Thresholds - 500lbs Load , 1.5 degrees Incline,  100Hz Vibration 

 these default 

threshold settings are NOT user changeable.    

 

DISPLAY   

The Rescue Guardian utilizes a state-of-the-art 2.7 inch front lit display developed to be 
readable in any lighting condition.  Ultra-Low power consumption and high resolution coupled 
a wide/symmetrical viewing angle ensure that all critical information is displayed legibly to the 
user.    

Summary of Contents for 22-796RG1

Page 1: ...Box 174 5260 Odense S Denmark Customer Service 800 435 9358 www paratech com Email Paratech paratech dk Phone 815 469 3911 Fax 815 469 7748 www paratech com E mail paratech paratech us OPERATION PREVE...

Page 2: ...DIAN LED Functional Overview 7 DISPLAY 7 BATTERY LID 8 CHARGING PROCEDURES 8 INSTALLING THE APPLICATION OR YOUR DEVICE 9 CONNECTING TO THE RESCUE GUARDIAN 10 RESCUE GUARDIAN APP OVERVIEW 11 BATTERY HA...

Page 3: ...use and has a vast array of applications Monitors Load Vibration Incline Movement Wirelessly Transmits Load change Vibration Incline data movement alarms Warning System 6 high powered amber LEDs 95dBA...

Page 4: ...and built to withstand harsh conditions it can be damaged if not properly handled and stored FCC Compliance Statement TBA CAN ICES 3 A NMB 3 A Canada TBA EUROPEAN TBA Contains FCC ID TBA Usage Precaut...

Page 5: ...en appropriately trained or have insufficient experience should not attempt activities that could result in injury to themselves or others Electrical Safety The Rescue Guardian will conduct electricit...

Page 6: ...batteries 18650 in or near objects that will produce a static electric charge Very quick pressure changes can cause 18650 batteries to malfunction Always charge on a fireproof surface Charge only in a...

Page 7: ...6 RESCUE GUARDIAN...

Page 8: ...ill enter a self calibration mode so it is imperative to NOT to move the unit for approximately 10 seconds as it powers up Threshold Settings Definition The point at which a sensor reading exceeds the...

Page 9: ...eal The Battery Lid is held in place by two captive 5MM Hex stainless steel screws and must be securely and hand tightened into place using a Battery Compartment Tool like the one shown below WARNING...

Page 10: ...internet connection Please use the following steps to connect to a Wi Fi network 1 Open Settings by tapping on the gear icon fig 1 2 Tap Connections Wi Fi 3 Turn Wi Fi on 4 Tap on a network to connec...

Page 11: ...uld be inserted on top of the yellow ribbon to allow for easy battery removal Tuck the excess ribbon back in between the batteries to avoid interference with the sealing gasket of the battery lid Step...

Page 12: ...11...

Page 13: ...12 Step 7 Once you select a Rescue Guardian to monitor it will show in the connected screen To Disconnect a Rescue Guardian Unit Press the Red X at the corner of the active tile...

Page 14: ...d and Incline readings Press the Incline tile and Vibration levels will show if activated Battery Level On PRG Nickname Serial Number Live Load Data Signal Strength Back to Dashboard Alarm On Off Sett...

Page 15: ...CD Display Time out This setting is used to conserve battery power You can set to time out or dim the front light of the display on the Rescue Guardian unit Note pressing one of the buttons on the Res...

Page 16: ...ds These out of the box settings will be updated from time to time for best practices out in the field 2 Set Thresholds Manually Load Incline Vibration for application specific needs 3 Customized Crea...

Page 17: ...der yellow dot to the desired level and pressing Set If you wish to remove the Alarm press Remove Pressing Back will take to the Live Screen An exact hertz vibration setting can be accessed and set It...

Page 18: ...hresholds activate the Visual Audible and Mobile alarms For Example Incline A strut is positioned at 45 degrees the Alarm threshold set at 2 degrees The Rescue Guardian is then armed The alarm will so...

Page 19: ...ings To add your own custom preset select the a dialogue box will open and you will be asked to name and save the preset To save the Pre set go to the individual sensor settings and move the sliders t...

Page 20: ...et Select Arm All on the Live Data Screen to activate Note If you want to modify any of the settings you must disarm or reset any alarms before changes will be saved If an alarm has been triggered and...

Page 21: ...ures and broadcasts events as they happen and stores them for future analysis or review Select the File you wish to review and the playback will be facilitated on the blackbox data screen If you wish...

Page 22: ...ill operate using four 4 CR123A lithium batteries as an alternative emergency power source Paratech has available adapter tubes Each tube holds two 2 CR123A batteries fig 2 CAUTION when putting the CR...

Page 23: ...y or rapid changes in humidity or temperature Places with large amounts of sand or dust Places where the Rescue Guardian will be in contact with chemicals Places where strong magnetism is emitted next...

Page 24: ...of the Rescue Guardian over the battery lid as shown below providing a point of attachment for the Magnet Assembly 22 796598 Clamp Clevis Assembly 22 796599 or Mini Clamp Assembly 22 796634 22 796598...

Page 25: ...e Rescue Guardian to be mounted to the tube of a Paratech Rescue Strut or other large diameter objects 22 796634 Mini Clamp Assembly Attaches to the Adapter Plate Assembly allowing the Rescue Guardian...

Page 26: ...surfaces that can accept a nail or screw allowing the Magnet Assembly or Suction Cup to be attached 22 796627 Suction Cup Attaches to smooth surfaces glass metal plastic etc and interfaces with the Mi...

Page 27: ...Pairing Passcode NFC Wireless Alarm Notification Mobile application notifications via BLE Push Button Actuation Force 3 5lbs momentary Push Button Mechanical Life 500 000 cycles Switch Boots Silicone...

Page 28: ...27 SERVICE Contact your local Paratech Dealer Or call us Paratech Incorporated P O Box 1000 Frankfort IL 60432 USA Phone 815 469 3911 Fax 815 469 7748 www paratech com E mail paratech paratech us...

Page 29: ...r obligations or liabilities in connection with the sale or use of this product Should there be any defects in the material or workmanship of the RESCUE GUARDIAN buyer should return the defective prod...

Reviews: