SafeAir™ M-600 Installation Guide
17
www.parazero.com
SafeAir M-600 V2 AUTO-ARM model
6
Operating Guidelines
SafeAir M-600 V2 AUTO-ARM model
6.1
Preflight
Initial Conditions:
The safety cover is on and the safety pin is in.
Finalize all the preflight procedures to your drone and payload. The following tasks are in
addition to the regular preflight tasks –
Check dampers not damaged
Turn off the power to the drone
Take off the safety cover
Carefully remove the safety pin
Turn on the power to the drone
Go back to a safety distance of at least 5 meters
6.2
Takeoff
When climbing, you must climb to approximately eight meters before the system is
armed. Climb until you hear a single long beep, and the LED is
GREEN
.
The system is now armed and ready for activation in case of an emergency.
6.3
Before Landing
When approaching landing, at approximately three to five meters from the takeoff altitude,
the parachute system automatically disarms. At that point, a long double-beep is heard and
the LED is
PURPLE
..
If the landing point is at a different altitude than the takeoff altitude, or the system did not
disarm for some reason in the air, which may occur when there is a sudden change in
atmospheric pressure, land the drone slowly while keeping it level. After three seconds, the
system disarms itself.
6.4
After Landing
First place the safety pin inside the canister.
After the pin is secure, place the safety cover over the parachute system.
Caution
It is advisable to insert the safety pin back, before turning the drone’s
power off. This will prevent unintentional parachute deployment