- 46 -
5 TROUBLESHOOTING
Fault
Possible cause
Procedure
The PARI SOLE N
does not heat up.
The power cord is not plugged
into the power adapter properly.
Check that the power cord is
seated correctly in the power
adapter power cord socket.
The power plug is not plugged into
the mains socket properly.
Check that the power plug is
seated correctly in the mains
socket.
No medication is
coming out of the
nebuliser.
The nebuliser nozzle is blocked.
Clean the nozzle [See also: 4.5
What should I do if ...].
The connection tubing is not con-
nected properly.
Check that both ends of the tubing
are seated properly.
The connection tubing is leaking.
Replace the connection tubing.
The nebuliser is
leaking.
A gasket is damaged.
Replace with a new set of gaskets
[See also: 4.5 What should I do if
...].
Fault table
In the event of faults that ...
In the event of faults that are not listed in this chapter, or if the suggested procedure
does not correct the fault, contact the PARI GmbH Service Center [See also: 7.4 Con-
tact].