(FIG.1)
www.fergusonshowrooms.com
©2018 Ferguson Enterprises, Inc. 08/2018
INSTALLATION(Fig.1)
1. Fasten mounting strap (B) to outlet box with two 8-32 screws (A).
2. Connect the white wire from the fixture to the white wire from the outlet box and the black wire from the fixture to
the black wire from the outlet box. Cover the two wire connections using the two provided wire connectors. Wrap the
two wire connections with electrical tape for a more secure connection. Connect the copper ground wires from the
fixture and from the outlet box to the ground screw on the circular strap.
Note: If you have electrical questions consult your local electrical code for approved grounding methods.
3. After wires are connected, tuck them carefully inside outlet box. Raise the front plate (D) over the mounting strap (B)
A
B
D
C
INSTALACIÓN (Fig.1)
1. Ajuste la correa de montaje (B) a la caja de salida con dos tornillos 8-32 (A).
2. Conecte el cable blanco del accesorio al cable blanco de la caja de salida y el cable negro del accesorio al cable negro
de la caja de salida. Cubra las dos conexiones de cables usando los dos conectores de cables provistos. Envuelva las
dos conexiones de cables con cinta aislante para una conexión más segura. Conecte los cables de tierra de cobre desde
el accesorio y desde la caja de salida al tornillo de tierra en la correa circular.
Nota: Si tiene preguntas sobre electricidad, consulte el código eléctrico local para conocer los métodos de conexión
a tierra aprobados.
3. Después de conectar los cables, colóquelos con cuidado dentro de la caja de distribución. Levante la placa frontal (D)
sobre la correa de montaje (B) y asegúrela con el tornillo de montaje (C)