ParkeFlyer)Flyer9x))–))The)Manual))–))parkeflyer.com)
15)
!
Memory&warning:
!If!ON!will!show!a!warning!when!the!available!eeprom!memory!is!
less!than!200!bytes!when!the!Tx!is!turned!on.!The!Tx!will!not!output!a!signal!until!the!
alert!is!cleared.!!
!
&
Alarm&warning:
!This!will!give!you!a!“heads!up”!if!your!beeper!is!silent.!If!on!and!the!
beeper!is!set!to!'0'!(Quiet)!you!will!receive!a!warning!on!startup.!This!has!been!added!
after!a!programing!session!left!a!user!flying!on!silent.!I!find!it!really!useful!!!
Mode:!Choose!between!MODE1,!MODE2,!MODE3!and!MODE4.!!
!
!
!
!
Trainer&/&PPM&In&&
!
!
!
This!menu!allows!the!PPMin!(trainer)!inputs!to!be!configured.!It!enables!the!RAW!PPM!
inputs!to!be!selected!to!replace!the!sticks!for!training!purposes.!The!student!
transmitter!does!not!need!to!have!the!same!model!setup!as!the!instructor.!All!the!
mixes!on!the!instructors!Tx!will!be!applied!to!the!student!inputs.!If,!for!example,!you!
have!expo!on!your!sticks,!this!will!be!applied!to!the!raw!trainer!inputs!when!they!are!
selected.!!
!
The!mode!entry!selects!how!the!PPMin!value!is!used:!!
!
Y
off!
Y
unused!
Y
+=!
Y
add!to!instructor!stick!value!
Y
:=!
Y
replace!instructor!stick!value!
!
The!%!entry!applies!a!weighting!to!the!PPMin!value!Y100!to!100,!Use!Y100!to!reverse!
the!input.!Use!values!closer!to!0!to!reduce!the!students!control!sensitivity.!The!src!
entry!selects!the!PPMin!channel!for!the!function.!!
!
The!sw!entry!selects!the!switch!used!to!action!the!trainer!operation.!Multiplier!1,0!to!
5,0!scale!for!PPMin!values!The!multiplier!does!as!it's!name!suggests.!It!multiplies!the!
Recommendation:!MODE!1,!if!you!are!in!Europe,!MODE!2!if!your!are!in!the!US!