English
9 / 12
ATT025-040
7 Alarm
list
Alarm
Code
Display
ATT
025-040
ATT
060-090
ATT
140-340
Reset
Delay
Defoult conditions to active the alarm
Stop
Compressor
Stop Dryer
Alarm
relay
A01
WARNING PROBE AD In-
letTemperature
X
X
X
A
4 s
AIN Ad Inlet Temperature
Y
N
Active
A02
WARNING PROBE Purge Air
Temperature
X
X
X
A
3 s
AIN Purge Air Temperature
N
N
Active
A03
WARNING PROBE Dewpoint
Meter
X
X
X
A
3 s
AIN Dewpoint Meter
N
N
Active
A04
WARNING PROBE Heater
Outlet Temperature 1
X
x
X
A
3 s
AIN Heater Outlet Temperature A PROBE Not Connected Or Faulty
N
N
Active
A05
WARNING PROBE Heater
Outlet Temperature 2
X
X
X
A
3 s
AIN Heater Outlet Temperature B PROBE Not Connected Or Faulty
N
N
Active
A06
WARNING PROBE Compres-
sor DischargeTemperature
Nu
X
A
3 s
AIN Compressor Discharge Temperature
Y
N
Active
A07
WARNING PROBE Thermal
MassTemperature
Nu
X
A
3 s
AIN Thermal Mass Temperature PROBE Not Connected Or Faulty
N
N
Active
A08
WARNING PROBE Capacitive
Level
NU
X
A
3 s
AIN Capacitive Level
N
N
Active
A09
ALARM FRIDGE High Pres-
sure by pressure switch
X
X
A
Immediate
DIN High refrigerant pressure switch Active
Y
N
Active
A10
ALARM FRIDGE High
Temperature by temperature
switch
X
Nu
A
Imm.
DIN High Temperature switch Active
Y
N
Active
A11
WARNING ADSORBER High
AD Inlet Temperature
X
X
X
A,
se T<13°C(**)
180s
N
N
Active
A12
ALARM FRIDGE Low AD Inlet
Temperature
X
X
A
180s
Y
N
Active
A13
WARNING ADSORBER High
Electrical Heater Temperature
Column 1
X
X
X
A,
se T<150°C(**)
5s
N
N
Active
A14
WARNING ADSORBER High
Electrical Heater Temperature
Column 2
X
X
X
X
A, se
T<150°C
(**)
5s
N
N
Active