background image

MPS-2 Series Sensor

CVM-102P

2

2

1

4

3

Sensor Pin Out

Pin #

1

Brown: 24VDC

2

White: NPN / PNP Open Collector Output

3

Blue:

0VDC

4

Black: NPN / PNP Open Collector Output

Output Modes

The MPS-2 Series Sensor has two independent NPN or PNP
open collector output signals. The Switch Output Mode has a
switch point programmed by the user at a specified pressure.
The Hysteresis Range 

(h)

 adjustment controls the output signal

0 to 100% below the Switch Point 

(H)

.

The Window Comparator Mode provides two Switchpoint Settings

(A)

 and 

(b)

 that control the output signals (NPN / PNP) between

two pressures. This is referred to as the “High / Low” setting.

h

H

off  

off

0

-30 in Hg

on

on

A

b

off

off

off

-30 in. Hg

0

on

on

Switch Output

Window Comparator Output

Operating Pressure Range

(V) Vacuum (0 to -30 inHg)

(R) Compound (-14.7 to +72.5 PSI)

bar:

0.001

bar:

0.01

Units of Measure

kPa:

0.1

kPa:

1

Display Resolution

mmHg:

1

kgf/cm

2

:

0.01

inHg:

0.1

PSI:

0.1

Media

Air and Non-Corrosive Gases

Pressure Port

N

: 1/8" NPT, 

R

: 1/8" BSPT, 

G

: 1/8" BSPP, 

M5:

 M5 Female

Proof Pressure

V

: 72.5 PSI, 

R

: 116.0 PSI

Operating Temperature

32 to 122°F (0 to 50°C)

Storage Temperature

14 to 140°F (-10 to 60°C)

Humidity

35 to 85% RH

Electrical Connection

C

: 4-Pin, M8 Connector, 

G

: 2m Grommet Open Lead

Power Supply

10.8 to 30VDC, Ripple Vp-p 10% Max., Reverse Voltage Protection

Display

3-Digit, 7-Segment LED

Display Refresh

0.1 to 3.0 sec. (Factory set at 0.1)

Output Circuit

NPN (Sinking) or PNP (Sourcing) Output, Open Collector Transistor 30VDC, 125mA

Switch Output

2 Output Signals, NPN or PNP, Normally Open or Closed, LED Indicator

Output Modes

Hysteresis or Window Comparator

Specifications

Brown V+

White 

Analog 1 to 5 VDC

Blue 0V

Black 

NPN / PNP Output

Lead Wiring