Replacing the lower perforated plate
Loosen the screws on the solenoid valve
plate.
Remove and replace perforated plate and
demisters.
Loosen the solenoid valve plate
Reaffi x the solenoid valve plate:
Use a dyamometric key to tighten the
screws, and take care to observe the following
torques:
— 25 Nm in the case of K-MT 1-4
Tighten the screws crosswise in accordance
with the sequence shown on the right.
Repeat the process once.
Next the new drying agent should fi ll up.
Correctly affi xing the solenoid valve plate
Fill with new drying agent and remount check valve plate
Risk of falls!
The dryer must not be misused as a climbing aid. The components have not
been designed for such loads and could fracture.
Only use approved climbing aids when fi lling the chambers.
Slowly fi ll up with new drying agent in the chamber. If necessary, use a funnel. Take spe-
cial note of the next step.
Ensure that the drying agent is fi lled into the chambers with a high bulk density.
Note:
To achieve an optimum bulk density, we recommend using a „snowstorm“
fi lling pipe available from the manufacturer.