background image

404XE Series Product Manual

 

 

20

 

 

Parker Hannifin Corporation

 

EMN Automation 

-

 Parker

 

Irwin, Pennsylvania

 

The limit/home switch installed on the 404XE is a proximity sensor tripped by 

a flag attached to the carriage.  On the switch body is an LED to indicate acti-

vation.  Normally open (N.O.), normally closed (N.C.), current sinking (NPN) 

and current sourcing (PNP) variations are selectable with the product.  Nor-

mally open sensors  are typically used for home and normally closed are typi-

cally used for limits.  With a current sinking sensor, the output lead provides a 

path to ground when activated, and with a current sourcing sensor, the output 

lead provides a positive (+) voltage potential relative to ground.  Refer to you 

controller

s manual for compatibility.  Limit/home switch information is below.  

See Appendix A for switch part numbers

.

 

Limit/Home Switch Information 

-

 404XE

 

 

Do Not Reverse Supply Potential

 

Reversing supply potential of the 404XE limit/home sensor will destroy the sensor.

 

404XE Limit/Home Switch Wiring Code

 

Power (+)

 

Brown

 

N.O. Output Signal

 

Black

 

N.C. Output Signal

 

White

 

Ground (

-

)

 

Blue

 

404XE Sensor Pack Wiring Code

 

Power (+)

 

Red

 

Limit 1

(1)

 Output Signal

 

Blue

 

Limit 2

(1)

 Output Signal

 

Orange

 

Home Output Signal

 

Green

 

Ground (

-

)

 

Black

 

Shield (Connect to Earth 

Ground)

 

Green w/ Yellow Stripe

 

(1)  

Limit 1 is the switch farthest from the connector on the sensor pack hous-

ing; Limit 2 is the switch closest to the connector.

 

404XE Limit/Home Switch Specifications

 

 

 

 

H2 or 

L2 

Option

 

H3 or 

L3 

Option

 

H4 or 

L4 

Option

 

H5 or 

L5 

Option

 

H6 or 

L6 

Option

 

H7 or 

L7 

Option

 

H8 or 

L8 

Option

 

H9 or 

L9 

Option

 

H11 or 

L11 

Option

 

H12 or 

L12 

Option

 

H13 or 

L13 

Option

 

H14 or 

L14 

Option

 

Switch Type

 

N.C.

 

N.O.

 

N.C.

 

N.O.

 

N.C.

 

N.O.

 

N.C.

 

N.O.

 

N.C.

 

N.O.

 

N.C.

 

N.O.

 

Logic

 

NPN

 

NPN

 

PNP

 

PNP

 

NPN

 

NPN

 

PNP

 

PNP

 

NPN

 

NPN

 

PNP

 

PNP

 

Input Power

 

5

-

30 VDC, 20 mA

 

Output

 

100 mA Max

 

Repeatability

 

+/

-

 10 µm Unidirectional

 

Reverse Polarity Protection

 

No

 

 Operating Temperature Range

 

-

26°C to +70°C

 

Vacuum Rating

 

1 x 10

-

3

 Torr

 

Cable Length

 

2.0 m from Switch 

 

3.0 m from End of Sensor Pack

 

5.0 m from Switch

(1)

 

(1)  

Includes locking connector at distance 150 mm from switch.

 

Chapter 3 

-

 Component Specifications

 

 

Motor Information

 

The M41, M42, and M46 motor options supply a Parker servo or stepper motor assembled to the positioner.  

For specifications and  setup and connection parameters, refer to the motor user guides available for down-

load from www.parkermotion.com.

 

Summary of Contents for 404XE Series

Page 1: ...Parker Automation Manual No 102 0988 01 Rev J 404XE Series Product Manual Effective October 3 2018 Supersedes August 20 2018 Electromechanical Positioning Systems...

Page 2: ...ty and warning requirements of the application are met The products described herein including without limitation product features specifications designs availability and pric ing are subject to chang...

Page 3: ...ns 404XE 13 Test Methodology 14 Techinical Data 404XE 15 Clean Room Preparation 19 CHAPTER 3 COMPONENT SPECIFICATIONS 20 Motor Information 20 Limit Home Switch Information 404XE 20 Encoder Information...

Page 4: ...ed Charts for 402 403XE Page 24 Clarified Lubricant Application for 402 403XE Page 41 Corrected Part Number for 403XE Riser Plate Page 46 Rev 3 October 1 2007 Page 31 Sensor Pack Wiring only Ground Wi...

Page 5: ...it in its application Please observe the following guidelines for handling and mounting of your new positioner DO NOT allow the positioner to drop onto the mounting surface Dropping the positioner can...

Page 6: ...the positioner after high duty operation Motor tempera ture may approach 60 C Electrical Shock DO NOT take apart or touch any internal components of the positioner while unit is plugged into an electr...

Page 7: ...any specification except motion of a standard unit before failure is 5 C to 40 C Specifications Are Mounting Surface Dependent Catalog specifications are obtained and measured when the positioner is f...

Page 8: ...ctor T15 700 633 H11 N C current sinking sensor pack VL carriage D3 D4 drives and Limit Home Sen sor Pack H12 N O current sinking sensor pack option are not offered with T01 travel models H13 N C curr...

Page 9: ...s standard dowel pinned toe clamped to M5 SM16 Parallel mounting A location X axis motor 3 00 M6 SM16 Parallel mounting B location P39 Y axis standard dowel pinned toe clamped to M7 SM16 Parallel moun...

Page 10: ...omation Parker Irwin Pennsylvania Assembly Diagrams 404XE Limit Home Switches Riser Plate Sensor Pack Inline Motor Block Base Hard Cover Motor Adapter Carriage Ballscrew Brake Linear Encoder Rotary En...

Page 11: ...404XE Series Product Manual 11 Parker Hannifin Corporation EMN Automation Parker Irwin Pennsylvania Dimensional Drawings 404XE Visit www parkermotion com for 2D CAD and 3D Models...

Page 12: ...404XE Series Product Manual 12 Parker Hannifin Corporation EMN Automation Parker Irwin Pennsylvania Dimensional Drawings 404XE...

Page 13: ...10mm Lead 20mm Lead T01 25 mm N A 42 0 81 N A N A N A N A N A 72 0 36 0 73 1 50 1 42 1 70 T02 50 mm N A 50 0 94 0 98 N A N A N A N A 72 0 36 0 73 1 50 1 61 1 89 T03 100 mm 33 mm 58 1 19 1 23 1 12 1 21...

Page 14: ...peak error measured by a laser interferometer and prism located at 37 5mm above the center of the table This type of measurement sums the X Y Z roll pitch and yaw errors Temperature deviations from t...

Page 15: ...ds 404XE Table Life with Normal Load 1000 10000 100000 0 100 200 300 400 500 600 700 800 900 1000 1100 1200 Load N Life km Short Carriage NL Option Long Carriage VL Option 404XE Table Life with Pitch...

Page 16: ...hey should be used in conjunction with the corresponding formulas on the following pages also available at www parkermotion com to establish the life relative to load for each bear ing four per table...

Page 17: ...404XE Series Product Manual 17 Parker Hannifin Corporation EMN Automation Parker Irwin Pennsylvania...

Page 18: ...404XE Series Product Manual 18 Parker Hannifin Corporation EMN Automation Parker Irwin Pennsylvania...

Page 19: ...urement location A point directly below a component may have a different particle count than at a side location Cleanroom class compatibility information for 404XE tables with cleanroom preparation R1...

Page 20: ...E Sensor Pack Wiring Code Power Red Limit 1 1 Output Signal Blue Limit 2 1 Output Signal Orange Home Output Signal Green Ground Black Shield Connect to Earth Ground Green w Yellow Stripe 1 Limit 1 is...

Page 21: ...ge 30 C to 110 C Cable Length 0 47 m Cable Material PVC 404XE Rotary Encoder Wiring Code Power Red Pin 1 Ground Black Pin 2 Channel A White Pin 3 Channel A Yellow Pin 4 Channel B Green Pin 5 Channel B...

Page 22: ...r Shaft mm in Outside Diameter mm in Length mm in Rated Torque Nm Torsional Stiffness Nm Clamp Screw Torque in lb Misalignment Radial Axial Angular C2 Oldham 6 3 0 25 25 4 1 00 31 8 1 25 4 75 0 291 0...

Page 23: ...ifications are based on the following conditions The positioner must be bolted down along its entire length The positioner must be mounted to a flat stable surface with flatness error less than or equ...

Page 24: ...lts to be used when mounting payloads to the carriage Excessive length bolts can cause damage or pin the table in position Riser Plates Most of the motors used with the 404XE have a taller profile tha...

Page 25: ...ter 3 for coupling clamp screw torque specifications DO NOT use Loctite on coupling screws If motor has a rear shaft rotate motor by rear shaft and check that carriage moves Hold carriage and attempt...

Page 26: ...1 Belt 515 4 M4 x 8 Button Head Screw 517 2 M5 x 10 Button Head Screw 539 4 M3 x 8 Button Head Screw 540 2 M5 x 20 Socket Head Cap Screw 541 4 M4 Ribbed Spring Washer Step 4 IF USING MOTOR POSITION C...

Page 27: ...ecess distance should match the distance recorded earlier Readjust until the distance is matched and tighten clamp screw to 13in lb Note once the Loctite 609 is applied this step should be completed w...

Page 28: ...on the sensor pack needs to be removed When adjusting the sensor pack switches the screws may be turned a maximum of 1 4 turn Any further loosening could result in the nut becoming disengaged If this...

Page 29: ...Amber smooth FOR CLEANROOM PREPARATION R12 R14 OPTION Braycote 803 Translucent white smooth and buttery Maintenance Frequency FOR BOTH STANDARD AND CLEANROOM PREPARATION Linear bearings and ballscrews...

Page 30: ...f Loctite 638 to the counterbore Step 4 Install the wedge into the end of the mandrel and insert mandrel wedge assembly into the drive screw shaft counterbore until the mandrel bottoms out at the shou...

Page 31: ...w shaft counterbore until the mandrel bottoms out at the shoulder Install the long socket head cap screw and tighten Step 11 Orient the encoder so that the mounting holes align with the tapped holes i...

Page 32: ...898 53 404XE Coupling 0 25 Bore Bellows 003 1898 65 404XE Coupling 0 375 Bore Bellows 003 1898 95 404XE Coupling 11mm Bore Bellows 003 2918 01 404XE Limit Home 5m Extension Cable Part Number Descripti...

Page 33: ...404XE Series Product Manual 33 Parker Hannifin Corporation EMN Automation Parker Irwin Pennsylvania See Chapter 2 for motor adapter drawings 002 3619 01 404XE Riser Plate 002 3618 01 404XE Toe Clamp...

Page 34: ...404XE Series Product Manual 34 Parker Hannifin Corporation EMN Automation Parker Irwin Pennsylvania Notes...

Page 35: ...Parker Hannifin Corporation Electromechanical Automation Divi sion 1140 Sandy Hill Road Irwin PA 15642 Tel 800 245 6906 www parkermotion com Email emn_sales parker com emn_support parker com...

Reviews: