Parker Hannifin Corporation
EMN Automation
-
Parker
Irwin, Pennsylvania
32
406LXR Series Product Manual
Chapter 4
-
Performance
Temperature Effect on Accuracy
0
0.2
0.4
0.6
0.8
1
1.2
1.4
50
250
450
650
850
1050
1250
1450
1650
1850
Travel (mm)
E
rr
o
r
(m
m
)
5 degrees C
10 degrees C
15 degrees C
20 degrees C
25 degrees C
30 degrees C
Thermal Effects on Repeatability
Repeatability will not be effected as long as the temperature remains constant. However the
repeatability will be effected as the temperature changes from one level to another. This is most
commonly experienced when starting an application cold. Then as the application runs the 406LXR
comes to its operational temperature. The positions defined when the unit was
“
cold
”
will now be offset
by the thermal expansion of the unit. To compensate for this offset, all positions should be defined
after the system has been exercised and brought to operational temperature.
Causes of Temperature Increases
One or more of the following conditions may effect the temperature of the 406LXR
base:
Ambient Temperature
This is the air temperature that surrounds the 406LXR.
Application or Environment Sources
Summary of Contents for 406LXR Series
Page 30: ...26 ...
Page 38: ...34 ...
Page 64: ...Parker Hannifin Corporation EMN Automation Parker Irwin Pennsylvania Notes ...
Page 65: ...Parker Hannifin Corporation EMN Automation Parker Irwin Pennsylvania Notes ...
Page 66: ...Parker Hannifin Corporation EMN Automation Parker Irwin Pennsylvania Notes ...
Page 67: ...Parker Hannifin Corporation EMN Automation Parker Irwin Pennsylvania Notes ...
Page 68: ......