1-5
English
Advanced Features
The 650 has additional features which can be accessed via the drive menu, or for the 650V and 650G using
DSE Lite. Refer to the product manual for details.
Flycatching
- When enabled, lets the drive start into a spinning load by doing a frequency search.
Skip Frequencies
– Two selectable avoidance frequencies and associated window for each.
PID
– Provides closed loop process control
.
S-Ramp
– When enabled, introduces a second order slope to the ramp for smoother transitions.
Configurable Outputs
– The digital outputs on the 650V & G are totally configurable.
Auto Restart
- After a fault, the drive attempts a number of restarts after a settable delay.
Custom Screens
- Allows the use of a Custom parameter to be displayed. (650V & G only)
Encoder
– Terminals 12 &13 (650V & G) can be used for a quadrature (not complementary) encoder input for
steady-state speed feedback.
COMPLIANCE
A comprehensive guide to product compliance is available in the full product manual.
Warning
– Where there is a conflict between EMC and safety requirements personnel safety shall always take
precedence.
Operation of this equipment requires detailed installation and operation instructions provided in the
installation/operation manual intended for use on this product. This information is provided on the CD ROM
included in the container this device was packaged in. It should be retained with this device at all times.
Caution
: This is a product of the restricted sales distribution class according to IEC 61800-3. It is designated as
“professional equipment” as defined in EN61000-3. Permission of the supply authority shall be obtained before
connection to the low voltage supply.
In a domestic environment this product may cause radio interference in which case supplementary mitigation
measures may be required.
This equipment contains electrostatic discharge (ESD) sensitive parts. Observe static control precautions when
handling, installing and servicing this product.
EMC Emissions
The 650 frame 1-3 is required to be installed in an enclosure providing 15dBs attenuation between 30-1000MHz
to ensure compliance with EN61800-3, category C1, unrestricted distribution.
The 650 frame 1 and 2 single phase supply models (TN only) comply with EN61800-3, category C1, unrestricted
distribution with a maximum cable length of 25m, and the 650 frame 2 and 3 three phase supply modules (TN
only) comply with EN61800-3, category C2, restricted distribution with a maximum cable length of 15m.
EMC Connections
For compliance with the EMC requirements, the “0V/signal ground” is to be separately earthed. When a number
of units are used in a system, these terminals should be connected together at a single, local earthing point.
Control and signal connections should be made with screened cables, with the screen connected only at the
VSD end. However, if high frequency noise is still a problem, earth screen at the non VSD end via a 0.1
μ
F
capacitor.
Note:
Connect the control and signal screens (at the VSD end) to the VSD protective earth point, and
not to the control board terminals.
This manual was downloaded on www.sdsdrives.com
+44 (0)117 938 1800 - info@sdsdrives.com