The Keypad
9-53
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames B, C & D
Changing the Product Code (3-button reset)
On rare occasions it may be necessary to change the default settings by changing the Product Code. The
Product Code is
detailed in Appendix E.
A special key combination is required to change the product code. This feature is only available at power-
up as a security measure.
The 3-button reset will take you to the POWER BOARD menu in the expanded SYSTEM menu
(highlighted in the diagrams below).
Note
If the unit is operating on 24V dc only for configuration purposes, the unit will trip on
UNDERVOLTAGE (DCLO) as to be expected. Press the "E" key to clear the trip message when it
appears.
6901 Keypad Combination
Hold down the keys opposite:
-
Power-up the drive, continue
to hold for at least 2 seconds
t
E
PROG
HOLD
POWER BOARD
7.5kW 400V
for example
E
POWER BOARD
menu at level
SYSTEM
POWER
LANGUAGE
DEFAULT TO 60HZ
REFORMAT FLASH
RESTART
EXIT TO BOOT
*
*
*
Select from the
expanded SYSTEM menu
see
diagram
below
M
IMPORTANT
We recommend the menus marked * above are only used by Parker SSD Drives or suitably qualified
personnel.
Note
The LANGUAGE menu currently contains selection for ENGLISH only.