Section 4.0

Unpacking

Section 14.0

Troubleshooting - High Pressure, Liquid Section

Problem:

  

Pump does not produce liquid flow, operates  

 

irregularly or does not maintain pressure. 

 

Cause: 

 

a)  Air in the hydraulic system.

 

b) Suction line excessively long.

 

c)  Suction tubing sized too small.

 

d) Failure of one of the check valves.

 

e)  Liquid inlet filter is blocked.

 

f)  High pressure seal excessively worn.

 

Solution:

   a)  Check inlet suction line and connections  

 

  for leaks and allow pump to flow freely  

 

  downstream so as to remove any air.

 

b) Shorten liquid supply line.

 

c)  Increase tubing ID size between reservoir  

 

  and pump inlet.

 

d) Clean or replace both inlet and outlet  

 

  check valve assemblies.

 

e)  Clean or replace liquid inlet filter.

 

f)  Replace high pressure seal assembly.

Problem:

  

When air is applied to pump the spool will not  

 actuate.

Cause:

  

Unregulated air pilot feed line pressure was  

 

shut off at the same time as regulated main  

 

air drive pressure. This caused the Pilot  

 

Control Valve to stop in an incorrect position 

 

at shutdown.

Solution:

   Assure unregulated pilot air, regulated air 

 

drive and shutoff valve are arranged as 

  

shown in the “Air Line Schematic” in  

 

Section 7.0. 

 

 

Turn off regulated air drive pressure.  

 

Pressure should now only be supplied to the  

 

unregulated pilot connection. 

 

 

Press the manual push button switch on  

 

either end of Pilot Control Valve (see image  

 

below). This will shift the Pilot Control Valve  

 

and then the spool to the position required for  

 

restart. Now supply pump with main regulated  

 

air pressure.

Pilot Control Valve

Use only originally specified parts when installing or 

maintaining high-pressure equipment and follow all 

Parker Autoclave Engineers maintenance and  

assembly procedures. Do not use any parts from 

other equipment to make repairs or modifications. 

Contact Parker Autoclave Engineers with any  

questions or if sufficient information to complete the 

installation, maintenance and operation of the  

equipment has not been included.

!

WARNING

Section 4.0

Unpacking

Section 15.0

Service

Parker Autoclave Engineers now require all pump repair 

be sent to an authorized repair facility. Contact Parker 

Autoclave Engineers for recommendations. Pumps  

returned for service should be accompanied with the 

model number, serial number, manufacture date and 

problems you are experiencing.

Summary of Contents for AHL Series

Page 1: ...AHL Series Pump Air Driven High Pressure Liquid Pump Operation and Maintenance Manual Manual 02 9242ME April 2022 ...

Page 2: ...s own analysis and testing is solely responsible for making the final selection of the products and systems and assuring that all performance safety and warning requirements of the application are met The products described herein including without limitation product features specifications designs availability and pricing are subject to change by Parker Hannifin Corporation and its subsidiaries a...

Page 3: ...roduct Specification 6 4 0 Unpacking 6 5 0 Tools 6 6 0 Installation 7 6 1 Compressed Air Supply 7 6 2 Liquid Section 8 7 0 Pump Start Up 8 8 0 Process Media 9 9 0 Pump Functionality 10 10 0 Suggested Maintenance 10 Troubleshooting Information 11 0 Repair Kit Options 11 12 0 AHL Series Drawings 12 13 0 Trouble Shooting Pneumatic Section 15 14 0 Trouble Shooting High Pressure Liquid Section 16 15 0 ...

Page 4: ... H L M E N F G O Description Description A Air Inlet I Air Piston Bumper B Top End Cap J Air Piston C Air Muffler K High Pressure Seal Assembly D Air Cylinder L Liquid Inlet Connection E Bottom End Cap M Inlet Check Valve F High Pressure Outlet Connection N Pump Head Body G Outlet Check Valve O Hydraulic Plunger H Pilot Valve ...

Page 5: ...pe 4 PLCS 17 55 445 71 Liquid Inlet Female 1 2 NPT Side View Note Each Mounting Bracket includes 2 9 16 14 29 holes for 1 2 Bolts All dimensions are for reference only and are subject to change without notice Primary Dimensions Inches Secondary Dimensions Millimeters A 1 8 NPT Thread Spool Air Inlet Opposite Main Air Supply 1 4 NPT Thread Isolation Drain Port See Note 8 00 203 20 8 47 215 10 16 94...

Page 6: ... contents carefully examined upon receipt from the carrier Make sure there is no obvious damage to the contents DO NOT use the equipment if any damage is evident If damage has occurred file a claim with the shipper before contacting Parker Autoclave Engineers Service Department Examine all material within the container and check against the packing list to be sure all items are accounted for and a...

Page 7: ...tion port on the pump is a female 1 FNPT and is located in the spool base housing An additional female 1 8 FNPT air pilot valve connection port is located in the middle plate at the opposite side of the 1 NPT air inlet This pilot connection must be plumbed to an unregulated and filtered air source The purpose of this connection is to aid in low pressure differential start up and restart of the pum...

Page 8: ... output flow NOTICE Outlet The outlet tubing ID must at minimum match the same size of the pump check valve gland port Refer to product literature for outlet connections details for each pump Reducing outlet tubing or connection will reduce output liquid flow capacity The high pressure tubing must be rated to at least the maximum pump output pressure WARNING Verify liquid pressure system is protec...

Page 9: ...automatically restart if there is a drop in downstream high pressure DO NOT exceed the maximum liquid pressure and temperature rating specified on the assembly drawing and label for your pump It is recommended to use a liquid relief valve or rupture disk to prevent over pressurization of your high pressure system DO NOT exceed the maximum air drive pressure listed on your pump label WARNING Sectio...

Page 10: ...erse action of step 1 the suction head will change to a compression stroke while the pressurize head will change to a suction stroke 8 The air pistons continue to move until a piston hits the pilot valve assembly in the second end cap which will again cause the spool to shift and divert air to move the pump in the opposite direction Section 4 0 Unpacking Section 10 0 Suggested Maintenance All pump...

Page 11: ...epair Kit Options Pump Model Number O Ring Material Spool Valve Kit Pilot Valve Kit Air Drive Kit Hydraulic Seal Upper Inlet Check Valve Kit Outlet Check Valve w Seal Full Rebuild Kit AHL33 2DSCTB Buna N RS AHL RP AHL RA AHL 2DC RH AHL33 TB RC 11 B RC 11 B RF AHL33 2DCTB AHL33 2DSCTC FFKM RS AHL RP AHL RA AHL 2DC RH AHL33 TC RC 11 C RC 11 C RF AHL33 2DCTC AHL33 2DSCTV FKM RS AHL RP AHL RA AHL 2DC ...

Page 12: ...Operation Maintenance Manual 04 22 02 9242ME AHL Series Pump 12 Section 4 0 Unpacking Section 12 0 AHL33 20 C Series Pump Drawing ...

Page 13: ...02 9242ME AHL Series Pump Operation Maintenance Manual 04 22 13 Section 4 0 Unpacking Section 12 0 AHL66 20SC Series Pump Drawing ...

Page 14: ...Operation Maintenance Manual 04 22 02 9242ME AHL Series Pump 14 Section 4 0 Unpacking Section 12 0 AHL118 20SC Series Pump Drawing ...

Page 15: ... d Replace o ring on bottom plunger two piece plunger designs or add Loctite 2760 thread locker with sealant on plunger threads one piece plunger designs Problem Pump will not run and air escapes through the small hole in the spool valve housing Cause Spool valve sleeve o rings are leaking Solution Replace and lubricate spool valve o rings Problem Pump will not run and air escapes through the pilo...

Page 16: ...Solution Assure unregulated pilot air regulated air drive and shutoff valve are arranged as shown in the Air Line Schematic in Section 7 0 Turn off regulated air drive pressure Pressure should now only be supplied to the unregulated pilot connection Press the manual push button switch on either end of Pilot Control Valve see image below This will shift the Pilot Control Valve and then the spool to...

Page 17: ...Maintenance Notes ...

Page 18: ...Operation Maintenance Manual 04 22 02 9242ME AHL Series Pump 18 Maintenance Notes ...

Page 19: ... Generators Compressed Air Gas Filters Condition Monitoring Engine Air Fuel Oil Filtration Systems Hydraulic Lubrication Cool ant Filters Process Chemical Water Microfiltration Filters Nitrogen Hydrogen Zero Air Generators FLUID and GAS HANDLING Aerospace Agriculture Bulk Chemical Handling Construction Machinery Food Beverage Fuel Gas Delivery Industrial Machinery Mobile Oil Gas Transportation Wel...

Page 20: ...0 67 280 900 parker belgium parker com BG Bulgaria Sofia Tel 359 2 980 1344 parker bulgaria parker com BY Belarus Minsk Tel 48 0 22 573 24 00 parker belarus parker com CH Switzerland Etoy Tel 41 0 21 821 87 00 parker switzerland parker com CZ Czech Republic Klecany Tel 420 284 083 111 parker czechrepublic parker com DE Germany Kaarst Tel 49 0 2131 4016 0 parker germany parker com DK Denmark Baller...

Reviews: