14
Table 2.1: Components Table List
FIL-4
Optional 20-MICRON PRE-FILTER- FOR
UNIT #2
REMOVES PARTICLES LARGER THAN 20-
MICRONS
FWF-1
FRESH WATER FILTER- FOR UNIT #1
REMOVES CHLORINE
FWF-2
FRESH WATER FILTER- FOR UNIT #2
REMOVES CHLORINE
HP-1
HIGH PRESSURE PUMP MOTOR ASSY-
FOR UNIT #1
PROVIDES MEMBRANES WITH HIGH
PRESSURE
HP-2
HIGH PRESSURE PUMP MOTOR ASSY-
FOR UNIT #2
PROVIDES MEMBRANES WITH HIGH
PRESSURE
M1
HIGH PRESSURE MOTOR FOR UNIT #1
ROTATES HIGH PRESSURE PUMP
M2
HIGH PRESSURE MOTOR FOR UNIT #2
ROTATES HIGH PRESSURE PUMP
M3
BOOSTER MOTOR FOR UNIT #1
ROTATES BOOSTER PUMP
M4
BOOSTER MOTOR FOR UNIT #2
ROTATES BOOSTER PUMP
MF-1
MANIFOLD ASSY-1 FOR UNIT #1
CONNECTS UNIT PLUMBING AND
INSTRUMENTATION
MF-2
MANIFOLD ASSY-2 FOR UNIT #2
CONNECTS UNIT PLUMBING AND
INSTRUMENTATION
MMF-1
MEDIA FILTER ASSY-1 FOR UNIT #1
PROVIDES PREFILTERATION FOR LARGE
PARTICLES
MMF-2
MEDIA FILTER ASSY-2 FOR UNIT #2
PROVIDES PREFILTERATION FOR LARGE
PARTICLES
OWS-1
AIR/OIL WATER SEPARATOR- FOR
UNIT #1
SEPARATES OIL AND AIR FROM THE INLET
WATER
OWS-2
AIR/OIL WATER SEPARATOR- FOR
UNIT #2
SEPARATES OIL AND AIR FROM THE INLET
WATER
P1
HIGH PRESSURE PUMP FOR UNIT #1
PROVIDES SYSTEM WITH HIGH PRESSURE
P2
HIGH PRESSURE PUMP FOR UNIT #2
PROVIDES SYSTEM WITH HIGH PRESSURE
P3
BOOSTER PUMP FOR UNIT #1
PROVIDES SYSTEM WITH INLET PRESSURE
P4
BOOSTER PUMP FOR UNIT #2
PROVIDES SYSTEM WITH INLET PRESSURE
PG-1-1 & PG-2-1
LOW PRESSURE GAGE
MEASURES INLET PRESSURE WITH RANGE 0-
300 PSI
PG-1-2 & PG-2-2
HIGH PRESSURE GAGE
MEASURES HIGH PRESSURE OF SYSTEM WITH
RANGE OF 0-2000
PV-1 & PV-2
PRESSURE VESSELS (ALL CAPACITIES) -
FOR UNIT #1
PRESSURIZES AND STORES MEMBRANES TO
PRODUCE POTABLE WATER
PV-3 & PV-4
PRESSURE VESSELS- FOR UNIT #1
(4200-6800 GPD SYSTEMS)
PRESSURIZES AND STORES MEMBRANES TO
PRODUCE POTABLE WATER
PV-5 & PV-6
PRESSURE VESSELS (ALL CAPACITIES) -
FOR UNIT #2
PRESSURIZES AND STORES MEMBRANES TO
PRODUCE POTABLE WATER
PV-7 & PV-8
PRESSURE VESSELS- FOR UNIT #2
(4200-6800 GPD SYSTEMS)
PRESSURIZES AND STORES MEMBRANES TO
PRODUCE POTABLE WATER
ST-1
STRAINER- FOR UNIT #1
STRAINES AWAY THE IMPPURTIES AT THE
INITIAL STAGE
ST-2
STRAINER- FOR UNIT #2
STRAINES AWAY THE IMPPURTIES AT THE
INITIAL STAGE
UV-1
OPTIONAL UV STERILIZER- FOR UNIT
#1
KILLS BIOLOGICAL GROWTH USING UV
RADIATION
UV-2
OPTIONAL UV STERILIZER- FOR UNIT
#2
KILLS BIOLOGICAL GROWTH USING UV
RADIATION
Summary of Contents for AQUA DUO A455C-2800
Page 15: ...15 Figure 2 4 Piping and Instrumentation Diagram 2800 3600 GPD ...
Page 17: ...17 Figure 2 6 Piping and Instrumentation Diagram 4800 6200 GPD ...
Page 32: ...32 Figure 2 26 Hose Tube Connection Instructions Figure 2 27 Tubing Fitting Internals ...
Page 63: ...63 8 DRAWINGS DIAGRAMS ...
Page 64: ...64 1 P ID ...
Page 65: ...65 ...
Page 66: ...66 ...
Page 67: ...67 ...
Page 68: ...68 2 GA Drawing ...
Page 69: ...69 ...
Page 70: ...70 ...
Page 71: ...71 ...
Page 72: ...72 ...
Page 73: ...73 ...
Page 76: ...76 4 Wiring Diagrams ...
Page 77: ...77 ...
Page 78: ...78 ...
Page 79: ...79 ...
Page 80: ...80 ...
Page 81: ...81 ...
Page 82: ...82 ...