Bulletin TI-SteamSR-M 

Installation, Operation and Maintenance Manual

Technical Information

 

Balston

®

 Series "SR" Steam Filters

Parker Hannifin Corporation

Industrial Gas Filtration and 

Generation Division

Haverhill, MA  •  1-800-343-4048

www.balstonfilters.com

2

For 3/4" and 1" Steam Lines

The Balston 23/75SR is recommended for applications in smaller lines with a steam flow up 
to 500 lbs. per hour.  The filter is complete with filter cartridge, steam trap, and bleeder valve.

For 1-1/2" Steam Lines

The Balston SP2-23/75SR and SP3-23/75SR (three 23/75SR steam filters manifolded to-
gether) handle steam flows of up to 1000 and 1500 lbs. per hour, respectively.  Each filter has 
its own steam trap to avoid "short circuiting".  A master trap, at the end of the inlet manifold, 
disposes of most condensate before it reaches the filters.  Manifolds can be connected to 
flow from left to right or right to left, allowing for convenient installation.

For 2" Steam Lines

The Balston SP4-23/75SR (four 23/75SR steam filters manifolded together) handles steam 
flow rates of up to 2000 lbs. of steam per hour.  Steam trap and manifold features are the 
same as for Model SP3-23/75SR. The Balston SP6-23/75SR (Six 23/75SR filters manifolded 
together) handles steam flow rates of up to 3000 lbs of steam per hour.

Capacities

Installation

Typical Installation - SP3-23/75SR Steam Filter

2" NPT INLET

MANIFOLD. REDUCED 

TO 1

1/2

" ON INLET END

ONLY. 

2" NPT OUTLET MANIFOLD

REDUCED TO 1

1/2

" NPT ON 

OUTGOING END ONLY. 

Summary of Contents for Balston SR Series

Page 1: ... CFR Part 110 The Balston SR Steam Filters are in full compliance with the 3A Accepted Practices Number 609 03 for producing steam of culinary quality The Balston SR Steam Filters have also been accepted by the USDA for use in federally inspected meat and poultry plants Bulletin TI SteamSR M USFDA USDA and 3A Compliance housing through the Balston Grade SR Microfibre Filter Cartridge outside to in...

Page 2: ...hour respectively Each filter has its own steam trap to avoid short circuiting A master trap at the end of the inlet manifold disposes of most condensate before it reaches the filters Manifolds can be connected to flow from left to right or right to left allowing for convenient installation For 2 Steam Lines The Balston SP4 23 75SR four 23 75SR steam filters manifolded together handles steam flow ...

Page 3: ... The Mud Leg and manifold end plugs see installation diagram have not been installed The filter may be installed to flow from left to right or from right to left whichever is more convenient for your application The inlet manifold is at a lower level than the outlet manifold This prevents steam conden sate from climbing into the filter housings Make sure that incoming steam is connected to this lo...

Page 4: ...tap water A continuous discharge of live steam accompanied by a violent bucket rattle indicates that the trap has lost its prime This can usually be corrected by closing the inlet valve for a few minutes and then gradually opening it Caution Remove all steam pressure from filter before removing trap After backflushing reassemble trap to filter using Rectorseal TM 5 or equivalent on the threads How...

Page 5: ...rial Gas Filtration and Generation Division Haverhill MA 1 800 343 4048 www balstonfilters com 5 Replacement Parts Order by part number Not by item number To ensure consistent product performance and reliability use only genuine Balston replacement parts and filter cartridges Replacement Parts for 23 75SR SP2 23 75SR SP3 23 75SR SP4 23 75SR and SP6 23 75SR ...

Page 6: ...lletin TI SteamSR M 03 18 2014 Parker Hannifin Corporation Parker Manufacturing UK Ltd Gas Separation Filtration Division EMEA Dukesway Team Valley Trading Estate Gateshead Tyne Wear NE11 0PZ United Kingdom Ph 44 0 191 402 9000 www parker com gsfe Parker Hannifin Corporation Industrial Gas Filtration and Generation Division 4087 Walden Ave Lancaster NY 14086 Tel 716 686 6400 Fax 877 857 3800 www b...

Reviews: