Flow Control Servovalves
Bulletin HY14-1450-M1/US
Bul 1450-M1pgs.p65, dd
11
Parker Hannifin Corporation
Hydraulic Valve Division
Elyria, Ohio, USA
Ordering Information
Series BD15 and BD30
Code
Description
N
Nitrile (Std.)
V
Fluorocarbon
Connector
Seals
Basic Model
BD
Code Description
A
Standard Valve
B
Intrinsic Safe,
Factory Mutual
C
Explosion Proof,
Factory Mutual
J
Explosion Proof,
CSA Approved
N
Explosion Proof,
ATEX Approved
See Note 1.
Flow
Supply
Pressure
Code
Description
B
2600–3000
(Standard)
C
2000–2500
D
1400–1950
E
1000–1300
F
700–950
G
200–650
H
0–3000
(5th Port)
See Note 3.
Code
15
30
Size
Options
Coil
Mounting Bolt Kit (U.S.)
BD15
BK07 (4) 5/16-18 x 1
BD30
BK46 (4) 5/16-10 x 3 1/4
BD 15
Code
Flow (GPM)
1
3.8 LPM (1 GPM)
2.5
9.5 LPM (2.5 GPM)
5
18.9 LPM (5 GPM)
10
37.9 LPM (10 GPM)
15
56.8 LPM (15 GPM)
20
75.7 LPM (20 GPM)
BD 30
Code
Flow (GPM)
20
75.7 LPM (20 GPM)
25
94.6 LPM (25 GPM)
30
113.6 LPM (30 GPM)
40
151.4 LPM (40 GPM)
BD30
Code
Description
E
C
2
B (Std.)
F
C
2
D
G
C
1
B
H
C
1
D
K
Intrinsic Safe
M
Explosion Proof
See Note 2.
BD15
Code
Description
A
C
2
B (Std.)
B
C
2
D
C
C
1
B
D
C
1
D
J
Intrinsic Safe
L
Explosion Proof
Code
m(A)
Ohm
A
60 (Std.) 60
B
15
1016
C
20
591
D
30
243
E
40
138
F
50
90
G
100
22
H
200
5.7
J*
30/30
118/118
K
80
36
* For intrinsic safe only.
Note 1: “B” Intrinsic Safe Option meets
Factory Mutual
Intrinsically Safe Class I, II and III, Division 1
Groups A through G. Refer to Parker Bulletin 1452.
“C” Explosion Proof meets:
Factory Mutual Explosion Proof
Class I, II, III, Division 1, Groups A through G
“J” Exposion Proof meets:
Canadian Standards Association
Class I, Groups A through D
Class II, Groups E, F and G
Class III
Refer to Parker Bulletin 1451.
“N” Explosion Proof meets:
ATEX Ex II2G EExm II T3 T
amb
45°C to -50°C
Request Parker Documentation Package: 1200074
Note 2:
Connector Location & Flow Polarity
(Standard connector over C
2
+ to B = P to C
1
flow).
C
2
B = Connector over Port C
2'
+ to Pin B = P to C
1
flow.
C
2
D = Connector over Port C
2'
+ to Pin D = P to C
1
flow.
C
1
B = Connector over Port C
1'
+ to Pin B = P to C
1
flow.
C
1
D = Connector over Port C
1'
+ to Pin D = P to C
1
flow.
Note 3:
Supply Pressure: Code “H” applies to 5th Port/External
Pilot Option. This requires the use of a blank orifice “-
00”. First stage pressure should be limited to 41.4 Bar
(600 PSI) and no less than 27.6 Bar (400 PSI).
Servo valve rated flow at 1000 PSID ±10%.