Parker EME
State of delivery
192-120149 N08 June 2014
17
In diesem Kapitel finden Sie
............................................................................................................... 17
Meaning of the status LEDs - Compax3 axis controller .................................................... 17
Mounting and dimensions C3H ........................................................................................ 18
Connections of Compax3H .............................................................................................. 21
Signal interfaces .............................................................................................................. 29
3.1
State of delivery
Compax3 is delivered without configuration!
After switching on the 24VDC supply, the red LED is flashing while the green LED is
dark.
Please configure the device with the help of the Windows-Software "Compax3
ServoManager"!
3.2
Meaning of the status LEDs - Compax3 axis controller
Device status LEDs
Right LED (red) Left LED (green)
Voltages missing
off
off
During the booting sequence
alternately flashing
No configuration present.
SinCos
©
feedback not detected.
Compax3 IEC61131-3 program not
compatible with Compax3 Firmware.
no Compax3 IEC61131-3 program
Hall signals invalid.
flashes slowly
off
Axis powerless
off
flashes slowly
Power supplied to axis; commutation calibration
running
off
flashes quickly
Axis powered
off
on
Axis in error state / error present / axis powered
(error reaction 1)
flashes quickly
on
Axis in error state / error present / axis not powered
(error reaction 2)
on
off
Compax3 faulty: Please contact us
on
on
The
internal
device status LEDs are only connected to the
external
housing LEDs,
if the RS232 jumper at X10 is fitted to the control and the upper dummy cover is
fitted.
3. Compax3 device description
Note on Compax3H:
This manual was downloaded on www.sdsdrives.com
+44 (0)117 938 1800 - info@sdsdrives.com