Technical
Characteristics
Multi-axis devices
48
192-120148N5 June 2011
Motor holding brake output
Motor holding brake output
Compax3
Voltage range
21 – 27VDC
Maximum output current (short circuit
proof)
1.6A
Securing of brake Compax3M
3.15A
UL-approval for PSUP/Compax3M
conform to UL:
according to UL508C
Certified
E-File_No.: E235342
The UL certification is documented
by a “UL”
logo on the device (type
specification plate).
Insulation requirements
Enclosure rating
Protection class in accordance with EN 60664-1
Protection against human contact
with dangerous voltages
In accordance with EN 61800-5-1
Overvoltage category
Voltage category III in accordance with
EN 60664-1
Degree of contamination
Degree of contamination 2 in accordance with
EN 60664-1 and EN 61800-5-1
Safety technology Compax3M
Safe torque-off in accordance with EN
ISO 13849-1: 2007, Category 3, PL=e
Certified.
Test mark MFS 09029
Please respect the stated safety
technology on the
type designation
plate
(see on page 9) and the circuitry
examples