Power
-
Refer to Figures 2-2 and
2-3 for specific motor
wiring instructions
OEM
Series
Motor
Compumotor
Indexer
Compumotor
To connect the OEM650 to the Compumotor
indexer, use the cable provided with the
indexer. The cable should fit into the OEM650's
25-pin D connector as shown in this figure. No
additional wiring is necessary. Refer to the
indexer's user guide for any specific instructions
associated with the Compumotor indexer.
Drive
Figure 2-6. OEM650 with Compumotor Indexer Test Configuration
OEM
s
e
r
i
e
s
REMOTE
REF
CURRENT
DUMP
VDC+
VDC-
A+
A-
B+
B-
POWER
FAULT
Power
-
Refer to Figures 2-2 and
2-3 for specific motor
wiring instructions
OEM
Series
Motor
To connect the OEM650 to a non-
Compumotor indexer or pulse generator,
use the pinouts of the OEM650's 25-pin D
connector as shown in this figure. Refer to
the indexer or pulse generator's user guide
for any specific instructions associated with
the device.
1 Step+
2 Di
14 Step—
15 Direction—
Connect to non-Compumotor
Indexer or Pulse Generator
Figure 2-7. OEM650 with non-Compumotor Indexer or Pulse Generator Test Configuration
Quick Test: OEM650X
1. Complete steps 1- 6 from the OEM650 Quick Test.
but do not
remove jumper #11 (Auto Test Function)
2. Connect the OEM650X to an RS-232C communications device
(i.e., computer, PLC, etc.). The OEM650X's communication
parameters are listed below:
❏
Baud Rate: 9600
❏
Data Bits: 8
❏
Stop Bit: 1
❏
Parity: None